Device Purpose

The QLAB Advanced Quantification Software System, through its new 3D Auto MV application, intends to improve cardiac diagnostics by offering a semi-automatic tool for detailed mitral valve quantification from Philips ultrasound image data. This is accomplished by integrating a machine-learning based segmentation engine with established morphological assessment algorithms, which enables automated 3D model generation and the reporting of a comprehensive suite of mitral valve parameters.

Summary

The Philips QLAB Advanced Quantification Software System is a software application package designed for viewing and quantifying image data obtained from Philips ultrasound systems. The latest iteration, version 15.0, introduces a significant enhancement: the 3D Auto MV cardiac quantification application, a new Q-App which aims to provide clinicians with a dynamic method for clinical quantification of the mitral valve by integrating existing technologies from QLAB HeartModel and TomTec-Arena 4D MV Assessment. The 3D Auto MV application operates as a semi-automatic tool, combining a machine-learning derived segmentation engine with morphological and functional assessment algorithms to analyze the mitral valve. This integration facilitates the semi-automatic creation of a 3D surface model of the mitral valve, with the system proposing initial anatomical landmarks that users can review, edit, or accept, thereby aiming to improve workflow. The underlying machine learning algorithm is specifically trained for the mitral valve and supports the introduction of several new measurement parameters (such as D-Shaped Annulus Perimeter, Maximum Prolapse Height, D-Shaped Annulus Area, and Total Open Coaptation Area) for a more comprehensive assessment. Non-clinical verification and validation, including algorithm training and a validation study, were performed to confirm its performance specifications.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

QLABUltrasound Quantification3D Auto MVMitral ValveCardiac QuantificationImage Processing SoftwareMachine LearningSegmentation EngineTomTec-ArenaEchocardiography Software

Device Metadata

Submission Number
K200974
Company
Philips Healthcare
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the machine learning algorithm in the 3D Auto MV application differentiate between normal and pathological mitral valve morphologies, and what was the diversity of the dataset used for its training and validation?; What is the inter-observer and intra-observer variability for the new mitral valve quantification parameters introduced by the 3D Auto MV application (e.g., D-Shaped Annulus Perimeter, Maximum Prolapse Height)?; Can the 3D Auto MV software be integrated with non-Philips ultrasound systems, or are there specific data acquisition protocols from Philips systems required for optimal performance of its quantification features?; How does the semi-automatic landmark proposal feature in the 3D Auto MV application impact workflow efficiency and reduce user input time compared to fully manual methods or previous semi-automatic tools?; What are the known limitations or specific patient populations and image quality scenarios where the 3D Auto MV application's accuracy or performance might be suboptimal?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
QLAB Advanced Quantification Software - Philips Healthcare | ESL FDA AI Device Intelligence