Medscape Medical NewsAll articles

Visage Breast Density

Visage Imaging GmbH • Radiology • 01/29/2021

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Visage Breast Density is an image processing software that employs a trained convolutional neural network to automatically assess breast density from mammography and digital breast tomosynthesis images, categorizing them according to the ACR BI-RADS Atlas 5th Edition. It serves as an adjunctive tool for radiologists, integrating with the Visage 7 platform to aid in the evaluation of breast tissue composition, with performance validated through comparison to radiologist consensus and a predicate device.

Summary

Visage Breast Density is a software application designed to assist radiologists in assessing breast tissue composition by automatically evaluating breast density from mammography studies. It utilizes a convolutional neural network (CNN) that has been trained on a substantial database of mammography exams. When applied to a mammography image, the CNN calculates likelihoods for four distinct breast density categories (A, B, C, or D) as defined by the ACR BI-RADS Atlas 5th Edition. The classifications from individual images within a study are then consolidated to provide an overall density assessment for the entire mammography study. This software functions as an add-on module for the Visage 7 medical imaging platform, which handles the distribution, viewing, processing, and archiving of medical images. The breast density assessment is performed on mammography studies stored on the Visage 7 server, with the results displayed via the Visage 7 client and stored back on the server. Indicated for use with compatible full-field digital mammography and digital breast tomosynthesis systems, Visage Breast Density provides adjunctive information and is not intended as a standalone diagnostic tool. Performance testing against two independent datasets, using consensus from board-certified radiologists as ground truth, demonstrated that the software achieves accuracies comparable to a predicate device for both categorical and binary (dense vs. non-dense) classifications.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Breast DensityMammographyConvolutional Neural Network (CNN)ACR BI-RADSImage Processing SoftwareRadiologyDigital Breast TomosynthesisAdjunctive ToolDensity AssessmentVisage 7

Device Metadata

Submission Number
K201411
Company
Visage Imaging GmbH
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. What specific architectural details of the convolutional neural network (CNN) contribute to its accuracy in classifying breast density categories, and how was the training dataset curated to ensure robustness across diverse patient populations?; How does the software handle variations in image quality or acquisition parameters from different mammography and digital breast tomosynthesis systems when assessing breast density?; What is the quantitative performance (e.g., sensitivity, specificity, AUC) of Visage Breast Density for each of the four BI-RADS categories and for the binary 'dense' vs 'non-dense' classification, beyond 'similar accuracy' to the predicate?; How does the merging algorithm combine individual image classifications into a general classification for the entire mammography study, especially in cases of intra-study density heterogeneity?; What impact does the integration with the Visage 7 system have on workflow efficiency for radiologists, and are there any limitations in its use as purely adjunctive information?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, deep learning, neural network, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server, network, platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Visage Breast Density - Visage Imaging GmbH | ESL FDA AI Device Intelligence