Medscape Medical NewsAll articles

Syngo.via RT Image Suite

Siemens Medical Solutions USA, Inc. • Radiology • 08/13/2020

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

The syngo.via RT Image Suite SOMARIS/8 VB50 is presented as a software tool to advance radiation therapy planning by offering enhanced multi-modality image visualization, manipulation, and precise contouring of tumors and organs-at-risk. It employs digital image processing methods, notably an expanded deep learning-based algorithm for automated organ segmentation, aiming to increase the efficiency and accuracy of preparing diverse radiation treatments.

Summary

The syngo.via RT Image Suite, software version SOMARIS/8 VB50, is described in the document as an image analysis software intended for use in radiation therapy planning. Its core function is to enable medical professionals to view, manipulate, visualize (in 3D and 4D), and compare medical images from various modalities such as CT, PET, MRI, and CBCT. The software is designed to aid in the segmentation of tumors and organs-at-risk, the creation and modification of contours, and the management of points of interest like the isocenter, thereby supporting case preparation for treatments including Brachytherapy, Particle Therapy, and External Beam Radiation Therapy. It incorporates a range of digital image processing tools for these tasks, including capabilities for multi-modality image fusion, both rigid and deformable image registration, and the generation of simple geometric treatment plans, with the final results being exportable to dedicated Treatment Planning Systems. This version of the software, SOMARIS/8 VB50, introduces several modifications and enhancements compared to its predicate (SOMARIS/8 VB40), as detailed in the document. These include improvements in routine and advanced contouring functionalities, structure set management, and deformable alignment tools. A significant update highlighted is the transition of automatic contouring for the head/neck region from a previous atlas-based method to a deep learning algorithm; this deep learning approach, utilizing a Deep Image-to-Image Network, has also been extended for automated organ segmentation in additional anatomical regions like the thorax and pelvis. The document states that performance data, derived from software verification, validation, non-clinical testing, and a specific algorithm evaluation involving 112 subjects, demonstrated that the updated software performs as intended. This evaluation reportedly showed the segmentation algorithm to have non-inferior or superior accuracy (using the DICE coefficient against manual annotations) compared to the predicate version, with newly added organs achieving a 100% detection rate.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Radiation Therapy PlanningImage SegmentationContouringMulti-modality ImagingDeep LearningOrgan-at-RiskDeformable Image Registration3D/4D VisualizationTreatment Planning SystemSynthetic CT

Device Metadata

Submission Number
K201444
Company
Siemens Medical Solutions USA, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Intervention
AI Function
Generation|Analysis
AI Subclass
quantification/feature localization|synthetic data generation

Relevant Clinical Questions

  • Q1. How does the performance of the deep learning-based automatic contouring for head/neck regions, as described in this document, compare to the previous atlas-based method in terms of accuracy, consistency, and processing time across diverse patient anatomies?; What specific anatomical landmarks are detailed in the documentation for the "Deep Image-to-Image Network" for organ detection, and how does the document address the robustness of this detection across variations in image quality or patient positioning?; Can the document provide more specifics on the validation dataset characteristics (e.g., patient demographics, pathology variety, scanner types) used to confirm the "non-inferior or superior performance" of the extended organ segmentation portfolio, particularly for the newly added thoracic and pelvic organs?; What quantitative improvements or user feedback metrics, if detailed in the supporting data, were observed with the simplified deformation visualization tool in deformable alignment, and how does the document suggest this impacts user workflow efficiency or interpretation accuracy?; Regarding the generation of a synthetic CT from MRI, what data does this document provide on its typical geometric accuracy and Hounsfield unit fidelity compared to an actual CT, and what are its validated clinical applications or limitations in treatment planning as per the performance data?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score35/100
SBOM Evidence✓ Detected in Summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials(software version)
✓ Detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, dataset, annotation)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SBOM, ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Syngo.via RT Image Suite - Siemens Medical Solutions USA, Inc. | ESL FDA AI Device Intelligence