Auto Lung Nodule Detection
Samsung Electronics Co.,Ltd. • Radiology • 08/31/2021
Device Purpose
The Auto Lung Nodule Detection system is a machine learning-driven software designed to enhance radiological assessment by acting as a second reader to identify suspected pulmonary nodules (10-30mm) on adult PA chest radiographs. Integrated with Samsung's S-Station platform, its clinical testing demonstrated a significant improvement in physicians' nodule detection performance, supporting its role as an adjunctive diagnostic tool.
Summary
The Auto Lung Nodule Detection system is a computer-aided detection (CADe) software developed by Samsung Electronics, designed to assist physicians in identifying suspected pulmonary nodules between 10 and 30 mm in size on adult PA chest radiographs. Utilizing machine learning algorithms, the software processes DICOM images acquired from Samsung Digital X-ray Imaging Systems and integrates with the S-Station operational software to display circular markers on duplicated images, indicating regions of high nodule probability. It functions as a second reader, meaning clinicians review the original images first, and it is explicitly not for use on patients presenting with lung lesions other than abnormal nodules. The device underwent extensive non-clinical software verification and validation, conforming to standards such as ISO 14971 (risk management) and IEC 62304 (software life cycle), to ensure it meets user needs and intended use specifications. Clinical performance testing was subsequently conducted to validate its efficacy. This involved radiologists evaluating a dataset of chest radiographs, first independently and then with the aid of the Auto Lung Nodule Detection software. The study measured nodule detection performance using sensitivity, false positives per image (FPPI), and the jackknife alternative free response receiver operating characteristic (JAFROC) figure of merit (FOM). The results demonstrated a statistically significant improvement in nodule detection performance for all participating readers when using the device, suggesting its potential to effectively assist radiologists in the interpretation of chest X-rays for pulmonary nodules.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What specific machine learning architectures or algorithms are employed by the Auto Lung Nodule Detection software, and how were they trained and validated prior to the described clinical performance testing?; How does the system's performance, particularly sensitivity and false positives per image, vary with different characteristics of pulmonary nodules such as size (within the 10-30mm range), density, and location within the lungs?; What was the detailed composition of the test dataset used in the clinical performance testing, including the prevalence of nodules, types of nodules, and the range of subtlety of these nodules?; The device is contraindicated for patients with lung lesions other than abnormal nodules. How does the system differentiate or react to the presence of other lung pathologies that might mimic nodules, and what is the potential impact on its detection accuracy in such scenarios?; Beyond the JAFROC figure of merit, sensitivity, and FPPI, were any other reader-centric metrics evaluated, such as the impact on diagnostic confidence, interpretation time, or overall workflow efficiency when using the Auto Lung Nodule Detection software?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly