Device Purpose

BoneMRI is an image processing software that utilizes a convolutional neural network to analyze 3D gradient echo MRI scans of the pelvic region, generating 3D images with enhanced bone-to-soft-tissue contrast by assigning Hounsfield Unit values. Its purpose is to improve the visualization of bone structures in MRI, demonstrating quantitative accuracy in morphology and radiodensity compared to CT scans for this specific anatomical area, though not for tumor diagnosis or as a CT replacement.

Summary

BoneMRI is a standalone image processing software application designed to enhance the visualization of bone structures in Magnetic Resonance (MR) images of the pelvic region, including the sacrum, hip bones, and femoral heads. It analyzes 3D gradient echo MRI scans acquired with a dedicated protocol to construct 3D tomographic radiodensity contrast images, referred to as BoneMRI images. The core technology employs a convolutional neural network with filter banks, where thresholding and scaling operations are applied to assign a Hounsfield Unit (HU) value to each volume element based on intensity and contextual information. This process aims to provide enhanced contrast between bone and surrounding soft tissue, with the resulting BoneMRI images delivered in DICOM format for viewing on existing PACS workstations. It is intended for use by imaging experts such as radiologists or orthopedic surgeons. Performance testing involved software verification and validation, alongside studies using retrospective clinical data to demonstrate enhanced imaging quality. A quantitative voxel-by-voxel validation on data from 61 patients, comparing BoneMRI images with co-registered CT scans of the pelvic region, showed clinically acceptable accuracy. Specifically, the results indicated a mean absolute cortical delineation error below 1.0 mm, mean tissue radiodensity deviation below 10 HU (below 55 HU for bone specifically), and a mean HU correlation coefficient above 0.80 (above 0.75 for bone specifically). These findings suggest BoneMRI accurately reconstructs 3D bone morphology, radiodensity, and radiodensity contrast, making it a useful tool for assessing the pelvic region. However, it is explicitly warned that BoneMRI images are not intended to replace CT images and should not be used for diagnosing or monitoring tumors.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

BoneMRIMRI EnhancementImage Processing SoftwarePelvic RegionBone VisualizationRadiodensity ContrastHounsfield UnitConvolutional Neural Network3D Gradient Echo MRIDICOM

Device Metadata

Submission Number
K202404
Company
MRIguidance B.V
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Generation
AI Subclass
image enhancement

Relevant Clinical Questions

  • Q1. How does BoneMRI's performance in visualizing subtle bone pathologies (e.g., microfractures, early osteonecrosis) within the pelvic region compare to standard MRI sequences, beyond gross anatomical delineation?; What are the specific parameters of the "dedicated MRI scan protocol" required for optimal BoneMRI image generation, and how sensitive is the output quality to variations in these acquisition parameters across different MRI scanners?; Given the warning against using BoneMRI for tumor diagnosis, what specific image characteristics or limitations in differentiating neoplastic tissue from bone led to this restriction, and could this be addressed with further algorithmic refinement?; How does the voxel-by-voxel Hounsfield Unit accuracy of BoneMRI compare to CT across different bone densities (e.g., cortical vs. trabecular bone) and in patients with varying bone metabolic states within the pelvic region?; Beyond qualitative visualization and the current Hounsfield Unit correlation, what is the potential for using BoneMRI's quantitative outputs for longitudinal monitoring of bone changes or for biomechanical modeling in the pelvic region?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score25/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(neural network, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
BoneMRI - MRIguidance B.V | ESL FDA AI Device Intelligence