Medscape Medical NewsAll articles

Eclipse II with Smart Noise Cancellation

Carestream Health, Inc. • Radiology • 04/02/2021

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The Eclipse II with Smart Noise Cancellation software aims to enhance the diagnostic quality of adult and pediatric radiographic images by significantly reducing image noise. It achieves this through a novel pre-processing module that employs a Convolutional Neural Network, specifically a U-Net architecture, trained to identify and mitigate noise, ultimately leading to improved image clarity and diagnostic confidence for clinicians.

Summary

The Eclipse II with Smart Noise Cancellation is a software designed for the digital enhancement of radiographic images generated by x-ray devices, applicable to both adult and pediatric patients, excluding mammography. It operates as an optional feature within the ImageView product application software, processing acquisitions from various digital radiography imaging receptors like Computed Radiography (CR) and Direct Radiography (DR) systems, including the Carestream DRX detector family. The core technological advancement is its "Smart Noise Cancellation" module, which functions prior to the standard Eclipse II image processing. This module utilizes a Convolutional Neural Network (CNN), based on a U-Net architecture and trained with clinical images featuring simulated noise, to accurately estimate and create a 2D map of the noise present in an acquired image. The scientific basis of the Smart Noise Cancellation lies in this trained CNN's ability to generate a "Noise Field" map, which facilitates the targeted reduction of noise in radiographic images before subsequent enhancement processes. This advanced noise reduction aims to improve critical image quality attributes such as brightness, latitude, contrast, detail, sharpness, and overall noise appearance, thereby assisting radiologists and physicians in making more confident diagnoses. Non-clinical testing, including analysis of difference images and an ideal observer evaluation using simulated lesions on chest images, showed no significant residual artifacts and either preserved or improved lesion detectability. Furthermore, clinical evaluations conducted by board-certified radiologists, employing visual difference preference scales and the RadLex scale for diagnostic capability, confirmed that the software with Smart Noise Cancellation delivers diagnostic quality images superior to those from the predicate software (Eclipse II without this module) across a range of examination types, detector technologies, and exposure levels.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Radiographic Image EnhancementSmart Noise CancellationConvolutional Neural NetworkU-Net ArchitectureDigital RadiographyComputed RadiographyImage Processing SoftwareSignal-to-Noise RatioDiagnostic Image QualityX-ray Imaging

Device Metadata

Submission Number
K202441
Company
Carestream Health, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Generation
AI Subclass
image enhancement

Relevant Clinical Questions

  • Q1. How does the performance of the Smart Noise Cancellation module, specifically the U-Net based CNN, vary with different types of anatomical regions or varying levels of initial image noise beyond those tested?; What is the quantitative impact of the Smart Noise Cancellation on radiation dose reduction potential, given that improved noise handling might allow for acceptable image quality at lower exposure levels?; Are there specific types of image artifacts that the Smart Noise Cancellation module might introduce or exacerbate, and what are the mitigation strategies if such artifacts compromise diagnostic information?; How does the training dataset for the CNN (clinical images with simulated noise) generalize to rare or atypical pathological presentations not included in the training data?; What is the computational overhead, in terms of processing time, introduced by the Smart Noise Cancellation module, and how does this affect clinical workflow efficiency in high-throughput environments?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score15/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, deep learning, neural network, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server, network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(environment)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Eclipse II with Smart Noise Cancellation - Carestream Health, Inc. | ESL FDA AI Device Intelligence