Medscape Medical NewsAll articles

Vantage Orian 1.5T, MRT-1550, V6.0

Canon Medical Systems Corporation • Radiology • 01/15/2021

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The Vantage Orian 1.5T, MRT-1550, V6.0 system is a diagnostic MRI device employing a 1.5 Tesla magnet and nuclear magnetic resonance principles to visualize diverse anatomical structures. It integrates the AiCE deep learning reconstruction processing unit to enhance image quality, with this update certifying its expanded utility across a broader range of anatomical regions, validated by performance testing that confirmed maintained or improved image detectability.

Summary

The Vantage Orian 1.5T, MRT-1550, V6.0, is a 1.5 Tesla Magnetic Resonance Imaging (MRI) system designed for diagnostic imaging. It produces cross-sectional transaxial, coronal, sagittal, and oblique images that display anatomical structures of the head or body, and is also capable of non-contrast enhanced imaging such as Magnetic Resonance Angiography (MRA). The system operates based on the principles of nuclear magnetic resonance (NMR), imaging the spatial distribution of protons and their inherent properties like proton density, T1 and T2 relaxation times, flow dynamics, and chemical shift. The use of contrast agents is optional, depending on the specific region of interest, and the images produced are intended to provide diagnostic information when interpreted by a trained physician. This MRI system incorporates the AiCE (Advanced intelligent Clear-IQ Engine) Reconstruction Processing Unit, which utilizes deep learning algorithms for image processing. This submission specifically details the expansion of AiCE's application to additional anatomical regions, including the spine (cervical, lumbar, thoracic), various musculoskeletal areas (shoulder, hip, elbow, wrist/hand, foot/ankle), pelvis (female, soft tissue, prostate), abdomen (liver, renal, pancreas), breast, and cardiac imaging, supplementing its prior use for head and knee imaging. The system features a 1.4m short, 3.8-ton magnet, Pianissimo™ scan noise reduction technology, and a gradient coil enabling a maximum field of view of 55x55x50 cm. Performance and bench testing, including model observer studies for low contrast detectability and a human observer study with 6 board-certified radiologists involving 55 studies, indicated that AiCE maintained or improved image quality and was statistically preferred over other filters, performing at a level comparable to or exceeding that of predicate devices.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Magnetic Resonance ImagingAiCE ReconstructionDeep LearningDiagnostic ImagingAnatomical Structures1.5 TeslaImage ProcessingNon-contrast MRALow Contrast DetectabilityObserver Study

Device Metadata

Submission Number
K202767
Company
Canon Medical Systems Corporation
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Generation
AI Subclass
image enhancement

Relevant Clinical Questions

  • Q1. How does the AiCE deep learning reconstruction algorithm specifically impact quantitative image metrics such as Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR) across the newly added anatomical regions?; What were the specific criteria and scale used in the human observer study that led to the 'statistical preference' for AiCE images, and were inter-observer variabilities assessed?; Can the AiCE reconstruction processing be customized or tuned by the operator for different clinical scenarios or patient types within the approved anatomical regions?; What is the computational time difference for image reconstruction with AiCE compared to standard methods, especially for complex datasets from the newly added regions like cardiac MRI?; Beyond low contrast detectability, were other aspects of image quality, such as edge sharpness or artifact reduction, specifically evaluated in the performance testing for the expanded anatomical applications of AiCE?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly