BriefCase, RIB Fractures Triage (RibFx)

Aidoc Medical, Ltd. • Radiology • 04/14/2021

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

BriefCase for RibFx Triage is an artificial intelligence-powered software designed to expedite the identification of acute rib fractures on chest CT scans by providing rapid notifications to radiologists, thereby optimizing workflow prioritization. Its methodology involves DICOM image analysis using a deep learning algorithm, which has demonstrated high sensitivity and specificity in detecting target pathologies and significantly reducing the time to radiological review for critical findings.

Summary

BriefCase for RibFx Triage is a radiological computer-assisted software designed to aid medical specialists in workflow triage by identifying and flagging suspected acute rib fractures in chest CT scans. The system utilizes an artificial intelligence algorithm to analyze DICOM images acquired via a hospital server and processed on a cloud server. Suspected cases of three or more acute rib fractures trigger notifications on a dedicated worklist application on the radiologist's desktop. These notifications, which include patient identifiers and the suspected pathology, also offer a compressed, non-diagnostic preview image to prompt the radiologist to prioritize review of the original images in the PACS, operating in parallel with the standard of care without altering images or the reading queue. The software's performance was evaluated in a multicenter study involving 279 chest CT cases. It demonstrated high accuracy in identifying three or more acute rib fractures, achieving an Area Under the Curve (AUC) of 0.976, a sensitivity of 96.7%, and a specificity of 90.4%. A key clinical benefit highlighted was the potential for significant time savings in radiological workflow. For true positive cases, the software's mean time-to-notification was 4.2 minutes, compared to a standard of care mean time-to-exam-open of 89.4 minutes, suggesting an average potential time saving of over an hour in initiating review for critical cases. The Negative Predictive Value (NPV) was 99.6%, while the Positive Predictive Value (PPV) was 52.9%.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Rib FractureTriage SoftwareArtificial IntelligenceChest CTDICOM ProcessingWorkflow PrioritizationRadiology NotificationDeep Learning AlgorithmImage AnalysisTime-to-Notification

Device Metadata

Submission Number
K202992
Company
Aidoc Medical, Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. How does the algorithm's performance (sensitivity, specificity, AUC) vary with different CT scanner models, acquisition parameters (e.g., slice thickness variations within the 0.5-5.0mm range), or image noise levels typically encountered in clinical practice?; Given the PPV of 52.9%, what is the anticipated impact on radiologist workload due to false positive notifications, and are there strategies to mitigate this, such as adjustable notification thresholds?; The study demonstrated an average time saving of 85.2 minutes for true positive cases; what is the distribution of this time saving, and how does it vary across different hospital settings (e.g., academic vs. community, ED vs. inpatient)?; How does the 'compressed, low-quality, grayscale, unannotated image' preview feature influence the radiologist's initial assessment and decision to prioritize, and is there a risk of misinterpretation even if labeled 'not for diagnostic use'?; What are the specific exclusion criteria for 'technically inadequate' studies (e.g., motion artifacts, severe metal artifacts), and how robust is the software in identifying and handling such studies before they lead to erroneous notifications?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cloud, server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
BriefCase, RIB Fractures Triage (RibFx) - Aidoc Medical, Ltd. | ESL FDA AI Device Intelligence