syngo.CT Lung CAD

Siemens Healthcare GmbH • Radiology • 03/31/2021

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The syngo.CT Lung CAD (VD20) is an advanced software device utilizing Convolutional Neural Networks to assist radiologists in the detection of solid and subsolid pulmonary nodules from multi-detector CT chest examinations. Its methodology encompasses image preprocessing with lung segmentation, CNN-driven nodule candidate generation and classification, and a novel CNN-based post-filtering module to enhance accuracy by reducing false positives, with studies confirming improved nodule detection rates when employed by radiologists.

Summary

The syngo.CT Lung CAD (VD20) is a software-based Computer-Aided Detection (CAD) tool designed to aid radiologists in identifying solid pulmonary nodules (between 3.0 mm and 30.0mm) and subsolid (part-solid and ground glass) nodules (between 5.0 mm and 30.0mm) in multi-detector computed tomography (MDCT) chest examinations. It functions as an adjunctive tool, processing images from multivendor CT scanners (16 or more detector rows) to highlight regions of interest (ROIs) that might be overlooked. The software can be integrated into clinical practice as either a concurrent first reader, assisting the radiologist during their initial review, or as a second reader after their primary assessment. Notably, the syngo.CT Lung CAD (VD20) is an algorithm that provides a list of nodule candidates to a separate hosting application, such as syngo MM Oncology, which is responsible for displaying the CAD marks on the images. The device's core technology relies on Convolutional Neural Networks (CNNs) for its main functions: preprocessing (including isotropic volume resampling and lung segmentation using a V-net CNN), candidate generation from subvolumes of the CT scan, and candidate classification to determine the likelihood of a detection being a nodule. Key enhancements in the VD20 version include new AI models for candidate generation and classification, regional configurability options, a CNN-based post-filtering module specifically aimed at reducing false positives caused by bony protrusions or detections in the colon, and bug fixes to improve lung segmentation, particularly in apical or basal lung regions. The effectiveness of these updates was supported by a retrospective reader study involving 20 readers and 232 cases, which demonstrated a significant improvement in pulmonary nodule detection by all readers using both reading workflows (concurrent and second reader) compared to unaided interpretation. Non-clinical testing further verified the software's performance and safety.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Pulmonary nodulesComputer-Aided Detection (CAD)MDCT (Multi-detector Computed Tomography)Convolutional Neural Networks (CNN)Deep LearningLung SegmentationFalse Positive ReductionAdjunctive ToolThoracic ImagingRadiologist Assistance

Device Metadata

Submission Number
K203258
Company
Siemens Healthcare GmbH
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection

Relevant Clinical Questions

  • Q1. How does the performance of the CNN-based post-filtering module in reducing false positives (e.g., from bony protrusions or colon) quantitatively compare to the previous version (VC30) or to systems lacking this specific module?; What were the specific algorithmic changes or training data enhancements related to the bug fixes for apical or basal-lungs under-segmentation, and what was the measured impact on segmentation accuracy in these regions?; The reader study showed improvement with both concurrent first reader and second reader workflows. Was there a statistically significant difference in overall diagnostic accuracy, sensitivity, or radiologist reading time between these two workflows when using syngo.CT Lung CAD (VD20)?; Given the multivendor compatibility claim and the range of supported CT acquisition parameters (e.g., voltage, slice thickness, kernels), how robust is the syngo.CT Lung CAD (VD20)'s performance across these variations, particularly concerning detection sensitivity and false positive rates?; What are the standalone performance metrics (e.g., sensitivity per nodule, false positive rate per scan) of the syngo.CT Lung CAD (VD20) algorithm for detecting different types (solid, part-solid, ground glass) and sizes of pulmonary nodules, especially at the lower detection limits (3mm for solid, 5mm for subsolid)?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score15/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, machine learning, deep learning, neural network, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange(bug fix)
✓ Detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, VDR/VEX detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, OBOM. These may be present in the full FDA submission.