Medscape Medical NewsAll articles

syngo.CT Brain Hemorrhage

Siemens Medical Solutions USA, Inc. • Radiology • 01/28/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

syngo.CT Brain Hemorrhage is an artificial intelligence-driven software designed to analyze non-contrast head CT DICOM images for the suspicion of acute intracranial hemorrhage, aiming to assist clinicians by prioritizing cases for review. Its methodology involves AI learning algorithms processing imaging data to provide notifications of potential ICH with high sensitivity and specificity, thereby acting as an informational triage tool within the radiological workflow.

Summary

syngo.CT Brain Hemorrhage is an image processing software utilizing artificial intelligence learning algorithms to assist qualified clinicians in analyzing and prioritizing non-contrast head CT DICOM images. Its primary function is to algorithmically identify findings suspicious of acute intracranial hemorrhage (ICH), providing a notification for worklist prioritization by making case-level output (suspected hemorrhage / no suspected hemorrhage) available to CT scanners or PACS systems. This software acts as an informational tool to support the review process and is not intended for direct diagnostic use, nor does it alter the original medical images. The software's efficacy was demonstrated in a retrospective stand-alone performance study involving 600 anonymized head CT cases from five international sites, with findings compared against a ground truth established by a consensus of three board-certified neuroradiologists. This evaluation yielded a sensitivity of 92.8% (95% CI: 89.3%-95.2%) and a specificity of 94.5% (95% CI: 91.3%-96.5%) for detecting ICH, surpassing the predefined 80% performance threshold, with an average image processing time of 13.67 seconds per case. The underlying science employs AI to analyze imaging data, serving as a triage and notification system that operates in parallel to standard workflows to flag suspicious cases for expedited review by clinicians.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

syngo.CT Brain HemorrhageArtificial IntelligenceIntracranial HemorrhageNon-contrast CTDICOMTriage SoftwareRadiological Image AnalysisSensitivitySpecificityWorklist Prioritization

Device Metadata

Submission Number
K203260
Company
Siemens Medical Solutions USA, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. What specific deep learning architecture or AI models are utilized by syngo.CT Brain Hemorrhage, and what was the diversity of the training dataset used to develop these models?; How does the algorithm's performance (sensitivity/specificity) vary across different subtypes or locations of intracranial hemorrhage (e.g., subdural, epidural, intraparenchymal, subarachnoid)?; What is the software's robustness to variations in CT image quality, acquisition parameters, or the presence of artifacts commonly encountered in clinical practice?; Beyond worklist prioritization, has any research been conducted on the impact of this tool on radiologist reading times or diagnostic accuracy when used as an assistive device?; What are the specific technical requirements for integrating syngo.CT Brain Hemorrhage with existing hospital PACS and RIS environments, and what level of IT support is typically needed?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, deep learning, algorithm, dataset, ground truth)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(environment)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
syngo.CT Brain Hemorrhage - Siemens Medical Solutions USA, Inc. | ESL FDA AI Device Intelligence