Device Purpose

The HeartFlow Analysis is a software device that provides a non-invasive, quantitative functional evaluation of coronary artery disease by analyzing CT DICOM data. It achieves this by creating a patient-specific 3D model of the coronary arteries and employing advanced physiological simulation, including a "Gen3 Solver", to calculate FFRct and other hemodynamic parameters, thereby aiding clinicians in diagnosis and treatment strategy.

Summary

The HeartFlow Analysis is a non-invasive software medical device designed for the clinical quantitative and qualitative analysis of coronary artery disease in clinically stable symptomatic patients. It processes previously acquired Computed Tomography (CT) DICOM data to generate a 3D computer model of the patient's coronary arteries. Utilizing this model, the software performs physiological simulations to compute FFRct, a mathematically derived quantity representing fractional flow reserve, along with other simulated hemodynamic data such as blood flow, pressure, and velocity. These outputs, presented in graphic and text formats, are intended to aid qualified clinicians in the assessment and treatment planning of coronary artery disease. The device is intended to support the functional evaluation of coronary artery disease and is to be used by clinicians in conjunction with the patient's clinical history and other diagnostic information. Its core technology includes semi-automated extraction of anatomical data from CT images, centerline detection, lumen boundary determination, and the ability to modify the anatomical model. The FFRct v3 iteration employs a "Gen3 Solver" with updated calculations for total coronary baseline flow and flow distribution. Validation studies for the device included stress testing and repeatability testing, with evaluations performed using previously acquired diagnostic images from clinical trials, ensuring the device's acceptability for its intended use.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

FFRctCoronary Artery DiseaseCT DICOMPhysiological Simulation3D ModelingHemodynamic AnalysisNon-invasive DiagnosisComputational Fluid DynamicsCoronary FlowSoftware Medical Device

Device Metadata

Submission Number
K203329
Company
HeartFlow, Inc.
Panel
Cardiovascular
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. What specific algorithmic changes in the "Gen3 Solver" differentiate its flow and distribution calculations from the "Gen2 Solver," and how do these changes impact the accuracy or clinical utility of FFRct values?; How does the exposure of interim calculations, such as mass and volume, in FFRct v3 enhance a clinician's ability to assess model accuracy or understand the basis of the FFRct computation?; What were the specific quantitative results from the stress testing and repeatability testing for FFRct v3, particularly concerning the performance of the Gen3 solver compared to its predicate?; Given that the software analyzes "static coronary CT images," what are the known limitations in simulating dynamic physiological conditions, such as maximal hyperemia or varying cardiac outputs, and how are these addressed or accounted for in the FFRct calculation?; How does the semi-automated tool for extraction of anatomic data handle challenging cases, such as significant calcification, motion artifacts, or complex bifurcations in CT images, and what is the typical inter-observer variability in the resulting FFRct values after clinician review and potential model modification?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
HeartFlow Analysis - HeartFlow, Inc. | ESL FDA AI Device Intelligence