Medscape Medical NewsAll articles

BriefCase

Aidoc Medical, Ltd. • Radiology • 12/29/2020

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Aidoc's BriefCase is an AI-powered radiological triage software that enables appropriately trained medical specialists to receive timely notifications for suspected critical findings across a suite of CT imaging applications including cervical spine, head, chest, and abdomen. The system uses an artificial intelligence algorithm to analyze DICOM images and provide non-diagnostic preview alerts to prioritize cases within the existing standard of care, aiming to reduce delays in attention to urgent conditions like fractures, hemorrhages, embolisms, and occlusions.

Summary

Aidoc's BriefCase is a radiological computer-aided triage and notification software designed to assist appropriately trained medical specialists in improving workflow efficiency. It analyzes various types of CT images—including cervical spine, non-enhanced head CT, CTPA, abdominal CT, contrast-enhanced chest CT (for incidental PE), and head CTA—to flag suspected positive findings for a range of pathologies. These pathologies include cervical spine fractures (linear lucencies), Intracranial Hemorrhage (ICH), Pulmonary Embolism (PE), Intra-abdominal Free Gas (IFG), incidental Pulmonary Embolism (iPE), and Large Vessel Occlusion (LVO). The software employs an artificial intelligence algorithm to process DICOM images, operating in parallel with standard image interpretation protocols. Its primary function is to expedite the triage process by alerting users to potentially critical cases, with a key update being the expansion of its indicated user base. The BriefCase system consists of server components (Aidoc Hospital Server and Aidoc Cloud Server) and a Worklist Application installed on the user's desktop. When the AI algorithm detects a suspected finding, it sends a notification to the Worklist Application, which includes patient information, the suspected pathology, and a compressed, unmarked preview image. These preview images are for informational purposes only and explicitly labeled "not for diagnostic use"; they do not mark findings or alter the original medical images. Clinicians are responsible for reviewing the full, original images per standard of care. This version of the device notably broadens the intended user population for these established functionalities from radiologists to "appropriately trained medical specialists," relying on previously established performance data for the underlying algorithms for each pathology.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

BriefCaseAI algorithmCT image analysisRadiological triageWorkflow prioritizationNotification softwareMulti-pathology detectionMedical specialist toolDICOM processingNon-diagnostic preview

Device Metadata

Submission Number
K203508
Company
Aidoc Medical, Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. What are the sensitivity and specificity metrics of the AI algorithm for each of the six indicated pathologies (cervical spine fracture, ICH, PE, IFG, iPE, LVO) as established in the data supporting their initial functionalities?; How does the 'appropriately trained medical specialist' user category impact the interpretation workflow and time-to-diagnosis compared to when the tool was indicated only for radiologists?; What mechanisms are in place to ensure that the non-diagnostic preview images are not mistakenly used for diagnostic decisions, especially by the broadened user base?; Given that new performance data was not submitted for the broadened user indication, what was the rationale or evidence supporting the safety and efficacy of expanding use to non-radiologist specialists for these diverse and critical findings?; Are there any specific limitations or differences in how BriefCase should be used by different types of 'appropriately trained medical specialists' (e.g., emergency physicians vs. neurologists vs. trauma surgeons) for the various pathologies?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cloud, server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
BriefCase - Aidoc Medical, Ltd. | ESL FDA AI Device Intelligence