AmCAD-UT
AmCad BioMed Corporation • Radiology • 09/08/2021
Device Purpose
AmCAD-UT is a software device intended to aid medical professionals in analyzing thyroid ultrasound images by offering AI-driven or user-defined region of interest contouring for nodules larger than 1cm. It employs AI, statistical pattern recognition, and quantification methods to provide detailed visualization and measurement of sonographic characteristics, thereby supporting clinical assessment for potential biopsy.
Summary
AmCAD-UT is a Windows-based computer-aided detection (CADe) software application developed by AmCad BioMed Corporation. It is designed to assist medical professionals in the analysis of thyroid ultrasound images obtained from standard ultrasound systems. The primary function of AmCAD-UT is to facilitate the detailed examination of user-selected thyroid nodules, specifically those larger than 1cm for which a biopsy recommendation is being considered. The system allows for the region of interest (ROI) around a nodule to be manually defined by the user or automatically suggested by an integrated AI contouring algorithm after the user indicates the nodule's location. Once the ROI is established and confirmed, AmCAD-UT processes the image to provide quantification and visualization of various sonographic characteristics. These characteristics include hyperechoic foci, echogenicity, texture, margin, orientation, and the presence of anechoic areas. The underlying technology combines artificial intelligence, statistical pattern recognition, and quantification methods to analyze these features. The software automatically generates a report based on user inputs and the analytical findings, which can be printed or saved as a PDF. Standalone performance studies have been conducted to validate the effectiveness of the AI-suggested ROI contouring, using ROIs labeled by a panel of specialists as the ground truth, demonstrating its utility in accurately determining nodule contours.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the performance of the AI-suggested ROI contouring compare to manual ROI definition by experienced radiologists in terms of accuracy, time-efficiency, and inter-observer variability for nodules larger than 1cm?; What specific AI algorithms and statistical pattern recognition techniques are employed for the quantification and visualization of sonographic characteristics (e.g., hyperechoic foci, echogenicity, texture, margin), and how were these models trained and validated against ground truth?; Are there particular types or complex presentations of thyroid nodules (e.g., those with poorly defined margins or cystic components) where the AI contouring algorithm or sonographic characterization shows limitations?; How does the integration of AmCAD-UT's quantification and visualization features influence a physician's diagnostic confidence and subsequent biopsy recommendations for thyroid nodules compared to standard ultrasound review alone?; What is the reported accuracy or performance metrics (e.g., Dice similarity coefficient for ROI, sensitivity/specificity for characterization) of the AI-suggested contouring and sonographic feature analysis based on the standalone performance studies using specialist-labeled ROIs as ground truth?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly