Medscape Medical NewsAll articles

QUIBIM Precision Prostate (qp-Prostate)

QUIBIM S.L. • Radiology • 02/04/2021

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

qp-Prostate is an image processing software package intended for trained medical professionals to view, process, and analyze prostate MR images using a client-server architecture and DICOM-compliant data. The device utilizes Apparent Diffusion Coefficient (ADC) post-processing with a mono-exponential model and Perfusion – Pharmacokinetics (PKM) post-processing via the Tofts model to generate quantitative parametric maps and facilitate structured PI-RADS v2.1 reporting, serving as an analytical tool rather than a diagnostic one.

Summary

qp-Prostate is a medical image processing software package designed for trained professionals, including radiologists specialized in prostate imaging, urologists, and oncologists, to aid in the visualization and analysis of prostate MR images. The software operates on a standard 'off-the-shelf' workstation, functioning via a client-server model where the server, installed within the hospital network, communicates with PACS through the DICOM protocol, and users access the platform via a web browser. Its core purpose is to facilitate image viewing, processing, and analysis of DICOM-compliant prostate MR images, but it explicitly does not perform a diagnostic function; patient management decisions should not solely rely on its results. Key features include query/retrieve interaction with PACS, a DICOM viewer with image manipulation and segmentation capabilities, and a structured reporting option based on the PI-RADS® v2.1 template. The system incorporates two main quantitative analysis plug-ins: Apparent Diffusion Coefficient (ADC) post-processing and Perfusion – Pharmacokinetics (PKM) post-processing. For ADC analysis, requiring T2-weighted and Diffusion Weighted Imaging (DWI) sequences, it applies a mono-exponential model after spatial smoothing and motion correction to calculate ADC values, representing water molecule mobility in tissues, and generates ADC parametric maps. For PKM analysis, requiring T2-weighted and Dynamic Contrast Enhanced (DCE) sequences, it uses the standard Tofts model (after smoothing, motion correction, and Arterial Input Function selection) to calculate Ktrans, kep, and ve parameters, reflecting tissue vascular environment, and produces corresponding parametric maps. Performance was validated using digital reference objects (DROs) for technical accuracy and a dataset of clinical prostate MR cases to assess algorithm performance (spatial smoothing, registration, segmentation, motion correction, AIF selection) and for comparison against a predicate device using 157 cases from various MRI vendors and field strengths.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

qp-ProstateProstate MRIImage Processing SoftwareDICOMQuantitative AnalysisApparent Diffusion Coefficient (ADC)Perfusion Pharmacokinetics (PKM)KtransPI-RADS v2.1Structured Reporting

Device Metadata

Submission Number
K203582
Company
QUIBIM S.L.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the performance of the automated Arterial Input Function (AIF) selection algorithm in the Perfusion-Pharmacokinetics module vary across different MR scanner vendors and field strengths, beyond the tested Siemens, GE, and Philips units?; What is the typical processing time for a complete prostate MR study, including ADC and Perfusion-Pharmacokinetics analysis, on a standard 'off-the-shelf' workstation meeting the recommended specifications?; Can the quantitative parameters (ADC, Ktrans, kep, ve) derived by qp-Prostate be reliably correlated with specific Gleason scores or other histopathological findings to improve risk stratification?; What level of training or expertise is recommended for users to effectively utilize the advanced segmentation tools and interpret the quantitative outputs of qp-Prostate for PI-RADS v2.1 reporting?; Are there plans to incorporate machine learning or AI-driven algorithms to further enhance the accuracy of segmentations or the predictive value of the quantitative parameters generated by qp-Prostate?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score40/100
SBOM Evidence✓ Detected in Summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials(software package)
✓ Detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server, network, platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(environment)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SBOM, ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
QUIBIM Precision Prostate (qp-Prostate) - QUIBIM S.L. | ESL FDA AI Device Intelligence