Medscape Medical NewsAll articles

HYPER AiR

Shanghai United Imaging Healthcare Co.,Ltd. • Radiology • 04/30/2021

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

HYPER AiR is a software-based image processing function designed to improve the quality of fluorodeoxyglucose (FDG) PET images by reducing noise and enhancing contrast. It achieves this by innovatively incorporating pre-trained convolutional neural networks into the established Ordered Subsets Expectation Maximization (OSEM) iterative reconstruction process, leveraging AI to distinguish and suppress noise while preserving image details.

Summary

HYPER AiR is a software-only image reconstruction technique designed for Emission Computed Tomography (ECT) systems, specifically for fluorodeoxyglucose (FDG) Positron Emission Tomography (PET) images. Its primary purpose is to enhance image quality for radiologists and nuclear medicine physicians by reducing noise and improving contrast. This software is intended for implementation on existing PET/CT devices, namely the uMI 550 and uMI 780, serving as an advanced alternative to their standard image reconstruction algorithms. The core science of HYPER AiR involves integrating pre-trained convolutional neural networks (CNNs) into the iterative Ordered Subsets Expectation Maximization (OSEM) reconstruction process. Unlike conventional OSEM, which relies on maximum-likelihood estimation techniques, HYPER AiR's CNN component is designed to distinguish between image noise and essential image details, selectively removing the noise and enhancing details. Performance verification using raw datasets from uMI 780 and uMI 550 scanners demonstrated HYPER AiR's ability to improve image contrast while suppressing background noise. Clinical image evaluations by three board-certified nuclear medicine physicians further confirmed that HYPER AiR produces images with better contrast and lower noise compared to traditional OSEM, with image quality deemed sufficient for clinical diagnosis.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

HYPER AiRImage ReconstructionNeural NetworksConvolutional Neural NetworkPET ImagingOSEMNoise ReductionImage ContrastFDGSoftware

Device Metadata

Submission Number
K210001
Company
Shanghai United Imaging Healthcare Co.,Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Generation
AI Subclass
image enhancement

Relevant Clinical Questions

  • Q1. How does the performance of HYPER AiR's pre-trained neural networks vary with different patient populations, FDG uptake levels, or acquisition protocols beyond those tested?; What specific architectures or training methodologies were used for the convolutional neural networks in HYPER AiR, and how were they optimized to distinguish noise from true image detail in FDG PET scans?; Are there any known limitations or potential artifacts introduced by the HYPER AiR algorithm, particularly in low-count statistics or unusual tracer distributions, compared to traditional OSEM?; How does the processing time for HYPER AiR reconstruction compare to standard OSEM on the uMI 550 and uMI 780 systems, and does this impact clinical workflow?; Could the HYPER AiR framework be adapted or retrained for use with other PET tracers beyond FDG, or for other emission tomography modalities?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(neural network, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
HYPER AiR - Shanghai United Imaging Healthcare Co.,Ltd. | ESL FDA AI Device Intelligence