Zebra Medical Vision Ltd. • Radiology • 09/15/2021

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

HealthCCSng is an AI-powered software designed to opportunistically analyze non-cardiac-gated CT scans for the detection and categorization of coronary artery calcium, providing radiologists with an estimated calcium detection category to aid in identifying potential coronary artery disease risk. Its methodology relies on automated image analysis of existing CT data to identify calcifications above 130 HU, validated through retrospective studies demonstrating high agreement with radiologist-defined ground truth, thereby offering a supplementary tool within the diagnostic workflow.

Summary

HealthCCSng by Zebra Medical Vision Ltd. is a non-invasive, post-processing software designed to aid in the evaluation of calcified plaques in the coronary arteries, which are indicative of coronary artery disease risk. It functions by analyzing existing non-cardiac-gated CT studies that include the heart, specifically for adult patients over 30 years old. The software employs an artificial intelligence algorithm to automatically detect and estimate coronary artery calcium. This process is integrated into the radiologist's standard workflow, receiving CT studies via Zebra’s Imaging Analytics Platform (IMA), validating them for compatibility, and then performing the analysis. The system is intended to be used opportunistically, leveraging the frequent use of CT scans for other purposes, like lung cancer screenings, to identify coronary calcification. The HealthCCSng algorithm quantifies calcium deposits (identified at 130 Hounsfield Units and above) and generates a three-tier estimated coronary calcium detection category: Low (0-99), Medium (100-399), and High (>400). Alongside this categorical output, it provides preview axial images displaying the detected calcium with annotations, intended for informational purposes to support the radiologist, not for stand-alone diagnosis or clinical decision-making. Performance was validated in a retrospective study using 447 anonymized CT chest cases, comparing its output to a ground truth established by radiologist consensus. The device demonstrated an overall agreement of 92.5% with the ground truth, successfully meeting its performance goals across various imaging parameters and CT scanner manufacturers.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Coronary Artery CalciumCT Scan AnalysisArtificial IntelligenceNon-cardiac-gated CTPost-processing SoftwareCalcified PlaquesOpportunistic ScreeningRadiology WorkflowCalcium Detection CategoryImage Analysis Software

Device Metadata

Submission Number
K210085
Company
Zebra Medical Vision Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the HealthCCSng algorithm differentiate coronary artery calcification from other high-density structures or artifacts within the thoracic cavity on non-cardiac-gated CTs, which often have motion artifacts?; What is the specific impact on diagnostic accuracy or patient management when using a 3-category calcium score (Low, Medium, High) from HealthCCSng compared to the more granular Agatston scoring or the 4-category system of its predicate device?; Given its opportunistic nature with non-cardiac-gated CTs, what is the sensitivity and specificity of HealthCCSng for detecting clinically significant coronary artery calcium in populations undergoing CT scans for non-cardiac indications, and how does this vary by the primary reason for the CT scan?; How does the performance of the HealthCCSng algorithm, specifically its 92.5% overall agreement, vary across different CT scanner manufacturers, slice thicknesses, radiation doses, and reconstruction algorithms beyond the general statement of being 'well supported'?; What are the typical processing times for HealthCCSng to analyze a CT study and deliver the calcium detection category and preview images within Zebra’s Imaging Analytics Platform (IMA), and how does this integrate with high-volume radiology practices without causing significant delays?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm, ground truth, annotation)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
HealthCCSng - Zebra Medical Vision Ltd. | ESL FDA AI Device Intelligence