Medscape Medical NewsAll articles

Transpara 1.7.0

ScreenPoint Medical B.V. • Radiology • 06/02/2021

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Transpara® 1.7.0 is a software device utilizing deep learning algorithms to assist physicians in interpreting digital mammography and tomosynthesis images by detecting and characterizing suspicious lesions. Its updated algorithms demonstrate improved, non-inferior performance in identifying calcifications and soft tissue abnormalities, including newly added support for Fujifilm DBT, aiming to enhance breast cancer screening accuracy and workflow.

Summary

Transpara® 1.7.0 is a software-only medical device designed as a concurrent reading aid for physicians interpreting screening full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) exams. Its purpose is to improve the detection and characterization of abnormalities suspicious for breast cancer and enhance workflow. The system employs 'deep learning' algorithms, trained on a large, biopsy-proven dataset of breast cancer, benign abnormalities, and normal tissue, to analyze FFDM images and DBT slices. It identifies suspicious calcifications and soft tissue lesions (including densities, masses, architectural distortions, and asymmetries), providing computer-aided detection (CAD) marks, region-specific suspicion scores (0-100), links between corresponding views, and an overall exam score (1-10) indicating cancer likelihood. Transpara® processes DICOM inputs and outputs results in a standardized mammography CAD DICOM format to clinical systems like PACS and RIS, operating as a virtual machine with user interface implementation handled by third parties. Non-clinical performance testing on an independent, multi-center dataset (7882 non-cancer, 1240 cancer exams) demonstrated Transpara® 1.7.0's effectiveness. For 2D FFDM, it achieved 94.7% sensitivity for calcifications at 0.11 false positives (FP)/image, and up to 92.6% sensitivity for soft tissue lesions at 0.17 FP/image. For DBT, overall sensitivity was 91.3% at 0.3 FP/volume. Compared to its predicate (Transpara® 1.6.0), version 1.7.0 showed non-inferior and improved Area Under the Curve (AUC) values on a common testset: 0.949 for 2D (vs. 0.929) and 0.931 for DBT (vs. 0.917). This updated version also introduces validated support for Fujifilm DBT systems, for which it demonstrated an AUC of 0.952. These enhancements are attributed to algorithmic changes aimed at improving detection accuracy across FFDM and DBT modalities.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

TransparaDeep LearningMammographyDigital Breast TomosynthesisComputer-Aided DetectionBreast Cancer ScreeningLesion DetectionCalcificationsSoft Tissue LesionsArtificial Intelligence

Device Metadata

Submission Number
K210404
Company
ScreenPoint Medical B.V.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection/diagnosis

Relevant Clinical Questions

  • Q1. What was the specific composition and diversity of the "large database of biopsy-proven examples" used for training the deep learning algorithms, particularly regarding rare cancer subtypes or challenging benign mimics?; How does the "exam score" calibration, aiming for approximately 10 percent of non-cancer mammograms in each category, account for variations in baseline population cancer prevalence and image acquisition protocols across different clinical sites?; What are the specific algorithmic changes in Transpara® 1.7.0 compared to 1.6.0 that led to the improved detection accuracy for FFDM and DBT, and the addition of Fujifilm DBT support?; The document mentions false positive rates per image for FFDM and per volume for DBT; what is the variability of these false positive rates across different breast densities and lesion conspicuity levels?; Given that the user interface implementation is by third parties, what are the critical performance characteristics or integration guidelines ScreenPoint Medical provides to ensure optimal and consistent presentation of Transpara's outputs to the end-user radiologist?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Transpara 1.7.0 - ScreenPoint Medical B.V. | ESL FDA AI Device Intelligence