Medscape Medical NewsAll articles

Volpara Imaging Software

Volpara Health Technologies Limited • Radiology • 07/27/2021

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Volpara Imaging Software utilizes raw digital mammography and tomosynthesis data to automatically perform a volumetric analysis, generating quantitative metrics of breast composition, including volumetric breast density and BI-RADS categorization. The system's methodology involves creating density maps to calculate fibroglandular tissue volume relative to total breast volume, providing adjunctive information and quality assurance data to aid healthcare professionals in breast assessment.

Summary

Volpara Imaging Software is an application designed to work with raw data from digital breast x-ray systems, including tomosynthesis, to provide a quantitative assessment of breast composition. The software automatically analyzes these images using a volumetric approach, calculating and quantifying a density map where each pixel represents the thickness of fibroglandular tissue. From this density map, it determines volumetric breast density by calculating the ratio of fibroglandular tissue volume to total breast volume estimates, processing standard mammographic views (CC and MLO) from both digital mammography and digital breast tomosynthesis (DBT) examinations. The software outputs several key metrics, including the volume of fibroglandular tissue, total breast volume, volumetric breast density percentage, average and maximum thickness of dense tissue, and the maximum volume of dense tissue over any 1 cm² region. Additionally, it provides image quality assurance metrics, with version 3.2 specifically including dose and pressure values. These numerical values, along with an automatically assigned BI-RADS breast density category (4th or 5th Edition) and the density maps themselves (marked with maxima), are presented via a Volpara scorecard (DICOM Secondary Capture Image) or a DICOM Mammography CAD Structured Report. The software, intended to aid healthcare professionals as adjunctive information for breast composition assessment and not as a standalone diagnostic tool, operates on server environments, with version 3.2 specifically deployable on a Microsoft Azure-connected virtual appliance.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Volumetric Breast DensityDigital MammographyTomosynthesisFibroglandular TissueDensity MapBI-RADS CategoryImage ProcessingQuantitative AssessmentQuality Assurance MetricsDICOM

Device Metadata

Submission Number
K211279
Company
Volpara Health Technologies Limited
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the algorithm differentiate between fibroglandular tissue and other breast tissues from raw x-ray data, especially across different vendor equipment and acquisition protocols?; What is the variability or margin of error in the calculated volumetric breast density and BI-RADS categorization compared to expert radiologist consensus, particularly in borderline cases?; How do the quality assurance metrics, such as dose and pressure (specifically mentioned for version 3.2), correlate with image quality and the accuracy of the density assessment?; What specific improvements in 'density sanity checking' were implemented in version 3.2, and how do these affect the reliability of results in challenging cases (e.g., implants, very dense or very fatty breasts)?; Could the quantitative density metrics provided by Volpara Imaging Software be used to longitudinally track changes in breast density over time, and what is the reproducibility of these measurements?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score15/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(environment)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Volpara Imaging Software - Volpara Health Technologies Limited | ESL FDA AI Device Intelligence