Medscape Medical NewsAll articles

MammoScreen 2.0

Therapixel • Radiology • 11/26/2021

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

MammoScreen 2.0 is an AI-powered software utilizing deep learning algorithms, trained on extensive mammography datasets, to assist radiologists in detecting and characterizing suspicious findings like soft tissue lesions and calcifications in both FFDM and DBT images. It aims to improve diagnostic accuracy by providing a quantifiable suspicion score and visual aids, with clinical studies demonstrating enhanced radiologist performance (AUC) when using the device as a concurrent reading aid.

Summary

MammoScreen 2.0 is a computer-assisted detection and diagnosis software designed as a concurrent reading aid for physicians interpreting screening mammograms, including both Full-Field Digital Mammography (FFDM) and Digital Breast Tomosynthesis (DBT). Its purpose is to help identify potential soft tissue lesions and calcifications and assess their level of suspicion. The software automatically processes the four standard mammographic views, generating a report with a "MammoScreen score" from one to ten for individual findings, each breast, and the overall exam, where higher scores indicate increased suspicion. Technologically, MammoScreen 2.0 employs medical image processing and machine learning, specifically deep learning modules trained on extensive databases of biopsy-proven cancers and normal tissue, to recognize suspicious features. This version (2.0) updates the algorithmic components of its predicate for improved FFDM accuracy and to enable DBT image processing. Clinical validation for MammoScreen 2.0 involved two multi-reader multi-case (MRMC) studies, one for FFDM and one for DBT, comparing radiologist performance with and without the software. For FFDM, utilizing data from the predicate device (MammoScreen 1.0) to which MammoScreen 2.0 demonstrated non-inferior standalone performance, radiologists using the software improved their average Area Under the ROC Curve (AUC) from 0.77 to 0.80. The standalone FFDM software performance (AUC 0.79 for version 1.0) was non-inferior to unaided radiologists (AUC 0.77). For DBT, radiologists using MammoScreen 2.0 improved their average AUC from 0.79 to 0.83. The standalone MammoScreen 2.0 performance on DBT (AUC 0.84) was found to be superior to the average performance of unaided radiologists (AUC 0.79). The software is intended to provide interpretable results, with suspicion scores traceable from the exam level down to specific findings.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

MammoScreen 2.0Computer-Assisted DetectionDeep LearningFFDM (Full-Field Digital Mammography)DBT (Digital Breast Tomosynthesis)Suspicion ScoreRadiologist PerformanceAUC (Area Under ROC Curve)Soft Tissue LesionsCalcifications

Device Metadata

Submission Number
K211541
Company
Therapixel
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection/diagnosis

Relevant Clinical Questions

  • Q1. How does the "MammoScreen score" calibration (1-10 scale) correlate with specific BI-RADS categories or probabilities of malignancy?; What were the specific sensitivities and specificities achieved by radiologists with and without MammoScreen 2.0 in the FFDM and DBT studies, beyond the overall AUC improvement?; The document mentions "large databases" for training deep learning modules; what is the diversity (e.g., ethnicity, breast density, equipment vendors) of these training datasets, and how might this impact generalizability?; How does MammoScreen 2.0 handle images from different mammography system vendors, and what are the specific "compatible mammography systems" mentioned in the indications for use?; What is the average processing time per case for MammoScreen 2.0 for FFDM and DBT modalities, and how might this impact clinical workflow?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, model training, machine learning, deep learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
MammoScreen 2.0 - Therapixel | ESL FDA AI Device Intelligence