Medscape Medical NewsAll articles

EFAI Intelligent Cardiothoracic Ratio (iCTR) Assessment System

Ever Fortune. AI Co., Ltd. • Radiology • 04/04/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The EFAI Intelligent Cardiothoracic Ratio (iCTR) Assessment System is software designed to automatically calculate the cardiothoracic ratio from adult posterior-anterior chest X-ray images. It employs an artificial intelligence algorithm to measure cardiac and thoracic diameters, providing quantitative data and annotated images to assist clinicians.

Summary

The EFAI Intelligent Cardiothoracic Ratio (iCTR) Assessment System is a software medical device designed for hospitals and clinics to automatically assess the cardiothoracic ratio (CTR) from posterior-anterior (PA) view chest X-ray images. Utilizing an artificial intelligence algorithm, the iCTR system measures the maximal transverse diameter of the heart and the maximal inner transverse diameter of the thoracic cavity to calculate the CTR. The system outputs a structured report including a preview of the compressed chest X-ray image with an annotation line indicating these measurements, the CTR result, and a trajectory of CTR records. It is intended for use by physicians or other licensed practitioners in various healthcare institutions for adult patients aged 20-80 years, as an assistive tool, not for standalone clinical decision-making. Clinical performance testing involved 840 eligible PA CXR images from three sites, demonstrating an accuracy of 0.95 for the EFAI iCTR-derived CTR compared to physician-derived CTR. The system incorporates quality control models to filter non-chest X-ray images (Sensitivity 0.99, Accuracy 0.99) and non-PA view images (Sensitivity 0.99, Accuracy 0.97), and an image clarity assessment. The annotation models for heart diameter and thoracic cavity diameter showed root-mean-square errors of 8.81mm and 14.3mm, respectively. Non-clinical testing included software verification and validation according to IEC 62304 and usability engineering per IEC 62366-1 and IEC 62366-2.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Cardiothoracic Ratio (CTR)Chest X-rayArtificial IntelligenceDICOMImage AnalysisMedical SoftwarePosterior-Anterior (PA) ViewDiameter MeasurementClinical PerformanceAccuracy

Device Metadata

Submission Number
K212624
Company
Ever Fortune. AI Co., Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the AI algorithm's performance in calculating CTR vary across different X-ray imaging equipment manufacturers and exposure settings?; What are the specific image quality parameters (e.g., inspiration level, rotation, penetration) that most significantly impact the accuracy of the iCTR system, and what are its tolerance levels?; What was the range and standard deviation of the root-mean-square-errors (8.81mm for heart, 14.3mm for thoracic cavity) for the annotation models, and how do these compare to manual measurement variability?; Beyond the stated 0.95 accuracy, what is the sensitivity and specificity of the EFAI iCTR system for detecting cardiomegaly (defined by a specific CTR threshold) compared to expert human readers?; How does the system handle atypical anatomies or chest X-rays with significant pathologies (e.g., pleural effusions, lung masses) that might obscure cardiac or thoracic borders?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm, annotation)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
EFAI Intelligent Cardiothoracic Ratio (iCTR) Assessment System - Ever Fortune. AI Co., Ltd. | ESL FDA AI Device Intelligence