Medscape Medical NewsAll articles

Philips EPIQ Diagnostic Ultrasound System, Philips Affiniti Diagnostic Ultrasound System

Philips Medical Systems • Radiology • 09/24/2021

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The Philips EPIQ and Affiniti Diagnostic Ultrasound Systems are enhanced with a new Liver Fat Quantification software module designed to provide quantitative metrics for liver fat assessment. This module employs two distinct methods: Attenuation Quantification, which measures the rate of ultrasound signal decay in liver tissue (attenuation coefficient), and Hepato-Renal Index Quantification, which calculates a comparative echogenicity ratio between the liver and kidney, to aid in the non-invasive evaluation of hepatic steatosis.

Summary

The Philips EPIQ and Affiniti Diagnostic Ultrasound Systems are intended for diagnostic ultrasound imaging and fluid flow analysis across a wide array of human body applications, including abdominal, cardiac (adult, fetal, pediatric), vascular, fetal/obstetric, gynecological, musculoskeletal, and small organ imaging, among others. These systems are designed for use by trained healthcare professionals in clinical environments such as clinics, hospitals, and at the point-of-care. The purpose of this update is to introduce two new software features for Liver Fat Quantification, enhancing the capabilities of these ultrasound platforms for assessing liver conditions. The new Liver Fat Quantification module comprises two distinct software features: (1) Attenuation Quantification, which measures the attenuation coefficient of ultrasound in dB/cm-MHz within a specified region of interest in the liver, and (2) Hepato-Renal Index Quantification, which calculates a ratio measure of the echogenicity (ultrasound brightness) of the liver parenchyma relative to that of the adjacent renal cortex. These new tools supplement existing liver quantification capabilities on the systems, such as Shear Wave Point Quantification (ElastPQ) and Shear Wave Imaging (ElastQ), which measure liver stiffness. The performance of these new fat quantification features was evaluated through Philips' internal design control processes, including requirements review, risk analysis, software verification and validation, and non-clinical bench performance testing against a reference device with similar functionalities.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Liver Fat QuantificationAttenuation QuantificationHepato-Renal IndexDiagnostic UltrasoundEchogenicityAttenuation CoefficientPhilips EPIQPhilips AffinitiSoftware ModuleNon-invasive Assessment

Device Metadata

Submission Number
K212704
Company
Philips Medical Systems
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. What is the diagnostic accuracy of the Attenuation Quantification and Hepato-Renal Index features in detecting and staging hepatic steatosis compared to established methods like MRI-PDFF or liver biopsy?; How do patient-specific factors such as Body Mass Index (BMI), skin-to-liver distance, or the presence of co-existing liver conditions (e.g., fibrosis, inflammation) affect the reliability and accuracy of these liver fat quantification measurements?; What are the specific cut-off values for the Attenuation Coefficient (dB/cm-MHz) and Hepato-Renal Index that correlate with different grades of liver steatosis, and how were these thresholds validated across diverse patient populations?; How does the integration of these new fat quantification features into the Philips EPIQ and Affiniti systems impact overall workflow efficiency and examination time for abdominal ultrasound procedures specifically targeting liver assessment?; Are there any known technical limitations or contraindications for using these specific liver fat quantification software features, and how do they compare in performance to similar quantification tools available on other ultrasound systems?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials
- Not detected
SaaSBOMSoftware-as-a-Service Bill of Materials(platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(environment)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SaaSBOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, ML-BOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly