Al-Rad Companion (Pulmonary)

Siemens Medical Solutions USA, Inc. • Radiology • 12/06/2021

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The AI-Rad Companion (Pulmonary) is an AI-powered software that analyzes adult CT DICOM images of the thorax, providing quantitative and qualitative assessments of lung structures and abnormalities. It employs deep learning algorithms for segmentation of lungs, lobes, lesions, and opacities, and measures features such as pulmonary density and bi-directional lesion diameters to support clinicians in evaluating lung diseases.

Summary

AI-Rad Companion (Pulmonary) is an advanced software-only medical system designed to assist clinicians in evaluating lung diseases by analyzing adult Computed Tomography (CT) DICOM images. Utilizing artificial intelligence (AI), machine learning, and deep learning, it performs post-processing tasks such as landmark detection, segmentation, and classification. Its core functionalities include segmenting and measuring the complete lung, individual lung lobes, and lung lesions; identifying regions with lower Hounsfield values indicative of certain lung conditions; and detecting areas with elevated Hounsfield values, distinguishing between different types of opacities. The software version VA13 enhances these capabilities with features like "Pulmonary Density" analysis for segmenting opacity regions and calculating their percentage relative to lung volumes, and "Bi-directional lesion diameter" for more comprehensive lesion measurement, supporting both cloud and on-premises (edge) deployment. The system provides quantitative and qualitative analytical results to support the clinical assessment of diseases of the thorax. For instance, the "Pulmonary Density" feature segments opacity regions and can assign results to ranges defined by established criteria (e.g., Bernheim et al.), while the "Bi-directional lesion diameter" feature adds the maximum orthogonal 2D diameter to existing lesion measurements. Performance data from non-clinical testing and clinical evaluation demonstrated its effectiveness: lung lobe segmentation achieved average DICE coefficients ranging from 0.94 to 0.96 on 250 datasets. Segmentation of opaque regions was validated on 150 datasets, with 93.0% of the percentage of opacity (PO) values falling within the 95% Limits of Agreement (LoA) when compared to human reads. The software has been validated for data from Siemens Healthineers, GE Healthcare, and Philips CT systems, delivering results in various image formats, including DICOM Structured Reports.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

AI-Rad Companion (Pulmonary)Computed Tomography (CT)Lung Disease AssessmentArtificial Intelligence (AI)Image Post-ProcessingLung SegmentationLesion MeasurementPulmonary DensityHounsfield UnitsDICOM

Device Metadata

Submission Number
K213096
Company
Siemens Medical Solutions USA, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the AI algorithm differentiate between various types of lung opacities (e.g., ground glass, consolidation) beyond just identifying elevated Hounsfield values?; What is the variability in performance (e.g., DICE coefficients, Limits of Agreement for opacity) when the software is applied to CT images acquired with different scanner parameters (e.g., slice thickness, radiation dose, reconstruction kernels) not explicitly covered in the validation?; How does the 'Pulmonary Density' feature's assignment to ranges, such as those defined by Bernheim et al., correlate with clinical severity or specific pathological diagnoses across diverse patient populations?; What are the specific computational requirements and average processing times for the AI-Rad Companion (Pulmonary) on both cloud and edge deployment models, and how might these impact real-time clinical workflow efficiency?; Beyond the listed validation with Siemens Healthineers, GE Healthcare, and Philips scanners, what is the robustness and generalizability of the AI algorithms when encountering images from other CT manufacturers or those with significant motion or beam-hardening artifacts?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score40/100
SBOM Evidence✓ Detected in Summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials(software version)
✓ Detected
ML-BOMMachine Learning Bill of Materials(machine learning, deep learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cloud)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(deployment)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SBOM, ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Al-Rad Companion (Pulmonary) - Siemens Medical Solutions USA, Inc. | ESL FDA AI Device Intelligence