Medscape Medical NewsAll articles

EchoGo Core (2.0)

Ultromics Limited • Radiology • 12/20/2021

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

EchoGo Core 2.0 is an advanced software application utilizing artificial intelligence to provide operator-assisted automatic quantification of left ventricular function from adult echocardiograms, aiming to support physicians in cardiovascular diagnosis. Its methodology involves AI-driven view classification, LV contouring, and calculation of key metrics like ejection fraction and global longitudinal strain, with its performance validated through rigorous testing against a reference comparator.

Summary

EchoGo Core 2.0, manufactured by Ultromics, is a software application designed to assist physicians in diagnosing cardiovascular conditions in adult populations by quantifying and reporting cardiac function from echocardiogram images. The system employs artificial intelligence for operator-assisted automatic quantification of common echocardiographic metrics, operating through a sequential workflow. This workflow includes automatic view classification (A2C, A3C, A4C) and labeling, which the operator confirms or relabels; AI-proposed contouring of the left ventricle; automated heart cycle identification with end-diastolic and end-systolic frame selection, which the operator approves; and finally, the calculation of clinical report metrics. The results are provided as secondary capture DICOM files or a structured DICOM report. The core technology of EchoGo Core 2.0 relies on AI algorithms for auto-view classification, auto-contouring with contours overlayed on images, DICOM handling, technical quality control, and automated calculation of metrics including ejection fraction (EF), global and segmental longitudinal strain (GLS, SLS) from A2C, A3C, and A4C views, and left ventricular (LV) volumes (including indexed values and non-Simpson's methods), length, and stroke volume. It also provides various visual representations like horseshoe and bullseye plots. Performance data from a retrospective validation study involving 214 unseen studies demonstrated its efficacy, achieving pre-determined acceptance criteria for Root Mean Square (RMS) error against a reference comparator (TomTec Arena TTA2). Reported RMS error percentages include 3.06-4.59% for LV length, 8.57-16.59% for LV volumes, 6.69-8.50% for EF, and 3.36-4.79% for GLS. The system also showed excellent inter-operator and intra-operator variability with a Deming RMSE of 0 for all reported metrics.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

EchocardiographyArtificial IntelligenceLeft VentricleCardiac FunctionImage Processing SoftwareDICOMEjection Fraction (EF)Global Longitudinal Strain (GLS)Automated QuantificationCardiovascular Diagnostics

Device Metadata

Submission Number
K213275
Company
Ultromics Limited
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the AI algorithm's performance in EchoGo Core 2.0, particularly for view classification and contouring, vary across echocardiograms with suboptimal image quality or rare cardiac pathologies?; What were the specific pre-determined acceptance criteria (RMS error thresholds) for each reported metric during the validation study, and what was the rationale for selecting these thresholds for clinical relevance?; Given the operator-assisted nature, what is the typical time saving or workflow efficiency gain observed when using EchoGo Core 2.0 compared to manual quantification methods or its predecessor, EchoGo Core 1.0?; Does EchoGo Core 2.0 offer capabilities for tracking changes in cardiac function longitudinally for the same patient, and how does it ensure consistency in measurements across different studies and operators?; What types of 'cautions' can the EchoGo Core 2.0 system generate for operator approval, and how does the AI determine when a caution is necessary regarding the quality or reliability of the automated analysis?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm, labeling)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
EchoGo Core (2.0) - Ultromics Limited | ESL FDA AI Device Intelligence