Viz ANEURYSM, Viz ANX

Viz.ai, Inc. • Radiology • 02/18/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Viz ANEURYSM is an AI-powered software designed to assist radiologists by rapidly analyzing CTA head images for suspected aneurysms (≥4mm) and prioritizing these cases for review via a mobile application. Its methodology relies on a machine learning algorithm to identify aneurysmal features, providing a non-diagnostic triage tool that significantly reduces notification times and demonstrates high sensitivity and specificity in clinical studies.

Summary

Viz ANEURYSM (Viz ANX) is a radiological computer-assisted triage and notification software specifically engineered for the analysis of Computed Tomography Angiography (CTA) images of the head. Its core function is to enhance workflow efficiency for hospital networks and trained radiologists by automatically flagging and prioritizing studies that exhibit suspected intracranial aneurysms measuring 4mm or greater in diameter. The system utilizes an advanced artificial intelligence (AI) and machine learning (AI/ML) algorithm. This algorithm processes CTA scans, which are automatically transmitted to Viz.ai’s backend server for analysis. Upon identifying a potential aneurysm, Viz ANEURYSM alerts users by highlighting the case within a dedicated standalone mobile application, Viz VIEW. This mobile platform presents compressed, non-diagnostic preview images, enabling clinicians to rapidly assess and prioritize cases for further detailed review using standard diagnostic tools, all while operating in parallel with existing standard of care image interpretation workflows and without altering the original medical data. The scientific basis of Viz ANEURYSM lies in its sophisticated AI algorithm's capacity to discern subtle image features indicative of aneurysms from CTA data. Clinical performance evaluations, conducted on a dataset of 315 scans, demonstrated robust efficacy: the software achieved a sensitivity of 93% and a specificity of 89% for detecting aneurysms of 4mm or larger, successfully meeting pre-defined performance benchmarks. The Area Under the ROC Curve (AUC) was calculated at 0.967, underscoring the classifier's strong discriminatory power. A key operational benefit highlighted was the significant reduction in time-to-notification; Viz ANEURYSM provided alerts in an average of 3.67 minutes, markedly faster than the 43.6-minute average observed in standard care pathways for the cases analyzed. It is designed as an adjunctive tool to support, not replace, radiologist expertise; diagnostic decisions remain the purview of radiologists using original images, and the software is limited to imaging data analysis for triage purposes.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Aneurysm detectionArtificial intelligenceCTA imagesRadiology workflowTriage softwareMobile applicationNeuro-radiologyImage analysisSensitivitySpecificity

Device Metadata

Submission Number
K213319
Company
Viz.ai, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. How does the AI algorithm differentiate between various types of intracranial aneurysms (e.g., saccular, fusiform) or features that might mimic aneurysms, especially for those near the 4mm detection threshold?; What was the variability in performance (sensitivity/specificity) observed across different CTA scanner models and acquisition protocols beyond the summarized manufacturer data, and are there specific scan parameters that optimize the algorithm's detection capabilities?; Given the significant time-to-notification improvement, what is the quantifiable impact on patient outcomes or downstream clinical decision-making in real-world hospital network settings where Viz ANEURYSM is implemented?; How does the algorithm's performance adapt to evolving aneurysm characteristics, such as growth, rupture, or post-treatment changes, if follow-up scans are processed through the system?; What are the computational load and data throughput requirements for the backend server processing, and how does the system scale to accommodate the imaging volume from a large, multi-site hospital network?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server, network, platform, backend)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(operational)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Viz ANEURYSM, Viz ANX - Viz.ai, Inc. | ESL FDA AI Device Intelligence