Aorta-CAD

Imagen Technologies, Inc • Radiology • 09/20/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Aorta-CAD is a software device employing a deep learning algorithm to analyze adult chest radiographs for findings indicative of chronic aortic conditions, specifically aortic calcification and dilated aorta. It functions as a concurrent reading aid for physicians, generating labeled bounding boxes around suspicious regions of interest to assist in the detection of Aortic Atherosclerosis and Aortic Ectasia.

Summary

Aorta-CAD is a computer-assisted detection (CADe) software designed to assist physicians in identifying suspicious regions of interest (ROIs) on adult chest radiographs that may indicate chronic aortic conditions. Employing a deep learning algorithm and computer vision techniques, the software analyzes these images and, if ROIs are detected, generates bounding boxes around them. These boxes are labeled with specific radiographic findings: "Aortic calcification," suggestive of Aortic Atherosclerosis, or "Dilated aorta," suggestive of Aortic Ectasia. Aorta-CAD produces a DICOM Presentation State file, an overlay that physicians can toggle on or off within their Picture Archiving and Communication System (PACS) viewer, functioning as a concurrent reading aid. The software is intended to support, not replace, the physician's judgment or other standard diagnostic procedures. The performance of Aorta-CAD was evaluated through standalone testing and a clinical reader study. In standalone tests involving 5,000 chest radiograph cases, the software demonstrated high overall sensitivity (0.910), specificity (0.896), and an Area Under the Curve (AUC) of 0.974. For specific findings, the AUC was 0.972 for Aortic calcification (sensitivity 0.922, specificity 0.894) and 0.948 for Dilated aorta (sensitivity 0.830, specificity 0.897). A multiple reader, multiple case (MRMC) retrospective clinical study with 244 cases showed that reader accuracy, measured by case-level AUC, was significantly superior when aided by Aorta-CAD compared to unaided readings (p < 0.001 for both categories). Specifically, reader AUC improved by 0.0984 for Aortic calcification and by 0.0885 for Dilated aorta when using the software.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Aorta-CADDeep learningChest radiographComputer-assisted detection (CADe)Aortic calcificationDilated aortaAortic AtherosclerosisAortic EctasiaRegion of Interest (ROI)DICOM

Device Metadata

Submission Number
K213353
Company
Imagen Technologies, Inc
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection

Relevant Clinical Questions

  • Q1. How does the Aorta-CAD algorithm's performance vary across different patient demographics (e.g., age, sex, BMI, presence of comorbidities) not explicitly detailed in the summary of the 5,000 case standalone assessment?; What is the typical processing time for Aorta-CAD per chest radiograph study in a real-world clinical setting, and how might this impact workflow efficiency in high-volume radiology departments?; The FROC curves terminate at the device’s box-level sensitivity due to the "cascaded nature of the Aorta-CAD predictions"; could you elaborate on this methodological aspect and its implications for detecting multiple or very subtle ROIs?; Given the Positive Predictive Value (PPV) for "Dilated aorta suggestive of Aortic Ectasia" was 0.296 in the standalone testing, what clinical guidance or training is provided to users to effectively manage the relatively high rate of false positives for this specific finding?; How robust is Aorta-CAD to variations in chest radiograph image quality, acquisition parameters, or X-ray equipment from different manufacturers, and were these variables assessed during the performance testing?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score20/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly