Aquilion ONE (TSX-306A/3) V10.12 with Spectral Imaging System, Vitrea Software Package, VSTP-001A
Canon Medical Systems Corporation • Radiology • 06/16/2022
Device Purpose
The Aquilion ONE (TSX-306A/3) V10.12 system enhances computed tomography by employing advanced methodologies like Deep Learning Reconstruction (PIQE), AI-driven noise reduction (AiCE), and expanded spectral imaging (including dual-energy brain scans) to improve diagnostic image quality, spatial resolution, and reduce radiation dose based on the science of X-ray attenuation and sophisticated image processing. The complementary Vitrea Software Package (VSTP-001A) V8.10 serves the purpose of advanced post-processing, utilizing updated spectral analysis tools to leverage the scanner's enhanced data for detailed material differentiation and sophisticated visualization, facilitating comprehensive clinical assessment.
Summary
The Canon Aquilion ONE (TSX-306A/3) V10.12 is a whole-body multi-slice helical CT scanner designed to acquire comprehensive cross-sectional volume datasets, enabling rapid imaging of entire organs like the brain, heart, and pancreas, often in a single rotation. Its methodology centers on advanced image acquisition and reconstruction technologies: PIQE, a Deep Learning Reconstruction algorithm, enhances spatial resolution and reduces noise for cardiac applications; AiCE, a Deep Convolutional Neural Network (DCNN) method, improves overall image quality and reduces noise across various anatomical regions including the abdomen, pelvis, lung, cardiac, brain, inner ear, and extremities. The system also introduces FIRST, an iterative reconstruction algorithm aimed at reducing radiation dose while improving high-contrast spatial resolution. A key scientific advancement is its enhanced spectral imaging system, featuring rapid kV switching for general spectral scans and a new dual-energy scan mode specifically for brain imaging, both designed to differentiate material compositions based on X-ray attenuation differences at distinct energies. Hardware modifications include a new SilverBeam Filter for dose reduction in applications like lung cancer screening, an increased maximum couch-top speed for faster scanning, and a redesigned, more intuitive user console. The Vitrea Software Package (VSTP-001A) V8.10, an application suite for the Vitrea medical image processing platform, provides sophisticated post-processing capabilities for images acquired from various modalities, including CT data from the Aquilion ONE. This software update specifically enhances its Spectral Analysis application to process data from the Aquilion ONE's new dual-energy brain scans (including AiCE-reconstructed images) and integrate segmentation data from Vitrea's CT Myocardial Perfusion and Coronary Artery Analysis tools. The updated Spectral Analysis provides richer visualization options, such as 3D rendering, Chamber View, polar maps, and advanced planar reconstructions (CPR, SPR). Performance testing via phantom studies confirmed the Aquilion ONE's PIQE algorithm provided superior high-contrast spatial resolution (8 lp/cm greater) and noise reduction compared to the previous AIDR 3D algorithm. The SilverBeam Filter was shown to effectively reduce dose while maintaining or improving image quality. Clinical images from the modified Aquilion ONE were confirmed to be of diagnostic quality by a board-certified radiologist. The Vitrea software enhancements were validated through bench testing, confirming they meet specifications and perform as intended for improved image analysis and visualization.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What are the specific quantitative improvements in noise reduction and spatial resolution achieved by PIQE and AiCE algorithms compared to previous generation Canon algorithms across different anatomical regions and patient populations?; How does the SilverBeam Filter specifically alter the X-ray spectrum to achieve dose reduction while maintaining or improving image quality for lung cancer screening, and what is the typical dose reduction percentage demonstrated in phantom or clinical studies?; What are the clinical scenarios where the expanded brain imaging capabilities of the Aquilion ONE's Spectral Imaging System (dual-energy scan) provide the most significant diagnostic advantages over conventional CT brain imaging?; Can the Vitrea Software Package's Spectral Analysis effectively differentiate and quantify specific material compositions beyond iodine, uric acid, and monosodium urate when processing data from the Aquilion ONE, and what are its limitations in complex tissue environments?; What is the impact of the increased couch-top speed on dynamic volume CT studies performed with the Aquilion ONE, particularly in terms of temporal resolution and potential for motion artifact reduction in uncooperative patients or rapid physiological processes?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of SBOM, ML-BOM, SaaSBOM, HBOM, OBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Not detected in AI-generated device summary: CBOM, VDR/VEX. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly