TOMTEC-ARENA
TOMTEC Imaging Systems GmbH • Radiology • 01/06/2022
Device Purpose
TOMTEC-ARENA (TTA2.50) is a medical image management and processing software that incorporates an artificial intelligence algorithm, specifically a Convolutional Neural Network trained via supervised learning, to provide semi-automated and editable echocardiographic measurements from B-MODE and DOPPLER data. The system is intended to assist physicians by enhancing the efficiency and consistency of quantifying cardiovascular, fetal, and abdominal structures and functions for diagnostic support.
Summary
TOMTEC-ARENA (TTA2.50) is a clinical software package designed for reviewing, quantifying, and reporting digital medical data to support physicians in diagnosing conditions related to cardiovascular, fetal, and abdominal structures and functions. A key update in this version is the introduction of semi-automated cardiac measurements powered by an artificial intelligence and machine learning (AI/ML) algorithm. This algorithm, a Convolutional Neural Network (CNN) developed using a supervised learning approach, processes B-MODE and DOPPLER echocardiographic datasets to suggest measurements. The AI/ML algorithm was trained by observing and learning from a large dataset of approximately 2,800 echocardiographic studies manually annotated by qualified healthcare professionals, and its performance was evaluated against a separate test pool of about 500 studies. When in use, the clinician selects an image frame, and the AI detector predicts the start and end caliper positions for a measurement. These AI-generated measurements are presented as editable graphical overlays, allowing the user to accept, modify, or reject the suggestion, or opt for manual measurement. This feature, integrated within the IMAGE-COM module, aims to streamline the quantification process without introducing new types of measurements.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What specific Convolutional Neural Network (CNN) architecture is employed, and what was the rationale for its selection over other potential AI/ML models for echocardiographic measurement?; Can you provide more detail on the characteristics of the ~2,800 training studies and ~500 test studies, including demographic diversity, range of pathologies, and image quality, to understand the algorithm's generalizability?; What were the quantitative performance metrics (e.g., agreement with expert manual measurements, mean error rates for caliper placement) of the semi-automated measurements on the independent test dataset for both B-MODE and DOPPLER data?; How does the system handle images of suboptimal quality or rare anatomical variations not extensively represented in the training data, and are there confidence scores or alerts for potentially less reliable AI-generated measurements?; What is the typical workflow impact, such as time saved per study or reduction in inter-observer variability, when clinicians utilize the semi-automated measurement feature compared to fully manual quantification?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of SBOM, ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly