Medscape Medical NewsAll articles

TOMTEC-ARENA

TOMTEC Imaging Systems GmbH • Radiology • 01/06/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

TOMTEC-ARENA (TTA2.50) is a medical image management and processing software that incorporates an artificial intelligence algorithm, specifically a Convolutional Neural Network trained via supervised learning, to provide semi-automated and editable echocardiographic measurements from B-MODE and DOPPLER data. The system is intended to assist physicians by enhancing the efficiency and consistency of quantifying cardiovascular, fetal, and abdominal structures and functions for diagnostic support.

Summary

TOMTEC-ARENA (TTA2.50) is a clinical software package designed for reviewing, quantifying, and reporting digital medical data to support physicians in diagnosing conditions related to cardiovascular, fetal, and abdominal structures and functions. A key update in this version is the introduction of semi-automated cardiac measurements powered by an artificial intelligence and machine learning (AI/ML) algorithm. This algorithm, a Convolutional Neural Network (CNN) developed using a supervised learning approach, processes B-MODE and DOPPLER echocardiographic datasets to suggest measurements. The AI/ML algorithm was trained by observing and learning from a large dataset of approximately 2,800 echocardiographic studies manually annotated by qualified healthcare professionals, and its performance was evaluated against a separate test pool of about 500 studies. When in use, the clinician selects an image frame, and the AI detector predicts the start and end caliper positions for a measurement. These AI-generated measurements are presented as editable graphical overlays, allowing the user to accept, modify, or reject the suggestion, or opt for manual measurement. This feature, integrated within the IMAGE-COM module, aims to streamline the quantification process without introducing new types of measurements.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

TOMTEC-ARENAMedical Image ProcessingArtificial IntelligenceMachine LearningConvolutional Neural NetworkEchocardiographySemi-automated MeasurementsCardiovascular QuantificationB-MODEDOPPLER

Device Metadata

Submission Number
K213544
Company
TOMTEC Imaging Systems GmbH
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. What specific Convolutional Neural Network (CNN) architecture is employed, and what was the rationale for its selection over other potential AI/ML models for echocardiographic measurement?; Can you provide more detail on the characteristics of the ~2,800 training studies and ~500 test studies, including demographic diversity, range of pathologies, and image quality, to understand the algorithm's generalizability?; What were the quantitative performance metrics (e.g., agreement with expert manual measurements, mean error rates for caliper placement) of the semi-automated measurements on the independent test dataset for both B-MODE and DOPPLER data?; How does the system handle images of suboptimal quality or rare anatomical variations not extensively represented in the training data, and are there confidence scores or alerts for potentially less reliable AI-generated measurements?; What is the typical workflow impact, such as time saved per study or reduction in inter-observer variability, when clinicians utilize the semi-automated measurement feature compared to fully manual quantification?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score35/100
SBOM Evidence✓ Detected in Summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials(software package)
✓ Detected
ML-BOMMachine Learning Bill of Materials(training data, machine learning, neural network, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server, network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SBOM, ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
TOMTEC-ARENA - TOMTEC Imaging Systems GmbH | ESL FDA AI Device Intelligence