Medscape Medical NewsAll articles

BriefCase

Aidoc Medical, Ltd. • Radiology • 03/21/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

BriefCase is a software device utilizing an artificial intelligence deep-learning algorithm to analyze head CT Angiography images for suspected Brain Aneurysms over 5mm, aiming to expedite workflow triage for medical specialists. It functions by providing notifications of potential positive cases to a desktop application, running in parallel to standard care, to facilitate earlier review of critical findings without altering the original diagnostic images.

Summary

BriefCase is a radiological computer-aided triage and notification software developed to analyze head CT Angio (CTA) images for the detection of potential Brain Aneurysms (BA) larger than 5 mm. Its primary function is to assist hospital networks and trained medical specialists by improving workflow triage through the flagging and communication of suspected positive BA cases. The system operates using an artificial intelligence algorithm that analyzes images and delivers notifications of suspect cases to a standalone desktop application, running in parallel with, and not replacing, the standard of care image interpretation. These notifications include compressed preview images, which are for informational purposes only and not for diagnostic use, ensuring the original medical image remains unaltered and is the basis for any clinical decisions. The technological foundation of BriefCase is a deep-learning algorithm specifically trained on head CTA images to identify BAs. The system architecture is comprised of three key modules: the Aidoc Hospital Server (AHS) for DICOM image acquisition, de-identification, and filtering; the Aidoc Cloud Server (ACS) for image processing using the AI algorithm; and the Aidoc Worklist Application, which provides the user interface for receiving notifications and viewing the worklist. A retrospective, multicenter pivotal study involving 268 cases (96 positive BA, 172 negative) demonstrated the software's efficacy, achieving a sensitivity of 88.5% and a specificity of 89.5%. Furthermore, the study highlighted significant potential for time-saving in clinical workflows, with the BriefCase system delivering notifications for true positive BA cases at a mean time of 4.2 minutes, compared to a mean standard-of-care time-to-exam-open of 89.4 minutes, suggesting an average time saving of over an hour.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Brain AneurysmCT AngiographyArtificial IntelligenceDeep LearningTriage SoftwareWorkflow PrioritizationRadiologyImage AnalysisNotification SystemClinical Performance

Device Metadata

Submission Number
K213721
Company
Aidoc Medical, Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. How does the algorithm's performance, with a sensitivity of 88.5% and specificity of 89.5% for brain aneurysms >5mm, change for aneurysms at or slightly below this size threshold, or with varying morphologies and locations?; What are the typical integration challenges and timelines for deploying the three-module BriefCase system (Aidoc Hospital Server, Aidoc Cloud Server, Aidoc Worklist Application) within existing hospital PACS and IT infrastructures?; Given the Positive Predictive Value (PPV) of 42.4%, what is the anticipated impact on radiologist workload from reviewing false positive notifications, and are there features to help manage or learn from these instances?; The study reported a mean time-to-notification of 4.2 minutes; how does this time vary with fluctuations in image data load or network latency between the hospital server and the cloud processing unit?; How robust is the BriefCase algorithm to variations in head CT Angiography (CTA) acquisition parameters, contrast timing, and image noise levels across different scanner models and manufacturers beyond those included in the pivotal study?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cloud, server, network, infrastructure)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
BriefCase - Aidoc Medical, Ltd. | ESL FDA AI Device Intelligence