Medscape Medical NewsAll articles

CardIQ Suite

GE Medical Systems SCS • Radiology • 03/11/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

CardIQ Suite is a non-invasive software application intended to analyze CT cardiovascular anatomy and pathology, aiding in diagnosis and treatment path determination by providing visualization, measurement, and advanced calcium scoring capabilities. It utilizes deep learning algorithms for automated calcium segmentation and scoring from DICOM CT data, supplemented by manual tools, and has shown performance comparable to existing methods in clinical evaluations.

Summary

CardIQ Suite is a non-invasive software application designed for the analysis of cardiovascular anatomy and pathology using 2D or 3D CT cardiac DICOM data, from both non-contrast and angiography acquisitions. Its primary purpose is to aid in the diagnosis and determination of treatment paths for various cardiovascular diseases, including coronary artery disease, functional heart parameters, heart structure abnormalities, and for follow-up on stent placements, bypasses, and plaque imaging. The software provides capabilities for visualizing and measuring vessels, assessing chamber mobility, and notably features a calcium scoring function to evaluate calcified plaques in coronary arteries, heart valves, and great vessels like the aorta, which can also be used to monitor calcium progression or regression over time. The technology integrates an automated calcium scoring component that utilizes a new deep learning algorithm for segmenting and labeling calcifications within coronary arteries, alongside traditional Agatston/Janowitz 130 (AJ130) and Volume scoring methods. While automation aims to improve workflow efficiency, CardIQ Suite also offers manual calcium scoring capabilities, allowing users to edit auto-scored lesions or manually score calcific lesions in various cardiac structures. The software includes a Coronary 2D Review toolset for interactive review of cardiac exams, including visualization of coronary artery paths and chamber motion. Non-clinical testing confirmed compliance with DICOM standards and successful design controls, while clinical testing involving three radiologists demonstrated very high correlations between manual scores (using a predicate device) and the automated scores from CardIQ Suite, indicating equivalent performance.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

CardIQ SuiteCardiovascular analysisCT DICOMCalcium scoringDeep learningCoronary artery diseasePlaque imagingAgatston scoreVessel visualizationChamber mobility

Device Metadata

Submission Number
K213725
Company
GE Medical Systems SCS
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the deep learning algorithm for calcium segmentation and labeling compare in accuracy and processing time to other commercially available AI-driven tools across diverse patient populations and varying image qualities?; What is the inter-observer and intra-observer variability associated with the manual editing features for calcium scoring, and how does this compare to the variability of the fully automated deep learning-based results?; Beyond the Agatston and Volume scoring methods, are there plans to incorporate advanced plaque characterization features, such as differentiating between calcified and non-calcified plaque or assessing plaque vulnerability, within the CardIQ Suite?; How does the 'Adaptive Volume' scoring method for calcium quantification differ from the standard Volume scoring, and what are the specific clinical scenarios or patient types where it might offer superior diagnostic or prognostic value?; What were the specific demographic and clinical characteristics of the patient cohort used in the retrospective CT exam database for validating the calcium scoring algorithm, and how does the algorithm perform on underrepresented patient groups or rare cardiac pathologies?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score35/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, labeling)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange(vulnerab)
✓ Detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, VDR/VEX detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
CardIQ Suite - GE Medical Systems SCS | ESL FDA AI Device Intelligence