Medscape Medical NewsAll articles

ABMD Software

HeartLung Corporation • Radiology • 07/29/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The ABMD Software is an AI-driven, post-processing tool designed to opportunistically measure bone mineral density from existing CT scans by analyzing Hounsfield Units in vertebral trabecular bone. Its methodology involves AI-based segmentation and HU averaging to calculate BMD, T-scores, and Z-scores, providing a non-invasive method for assessing bone health without additional radiation exposure.

Summary

The ABMD Software is an AI-powered, post-processing tool designed to opportunistically measure bone mineral density (BMD) from existing CT scans of the vertebral bones. Its primary purpose is to enable retrospective BMD assessment, allow BMD evaluation during CT scans ordered for other medical reasons, or facilitate phantom-less BMD measurement, all without subjecting patients to additional radiation beyond their initial CT scan; the software analyzes DICOM CT images, extracts patient and scan metadata, and utilizes an AI model to segment vertebral bones. Following segmentation, the ABMD Software measures the average Hounsfield Units (HU) within a cylindrical volume of the trabecular tissue in each vertebral bone, ensuring exclusion of cortical bone, and the mean of these HU averages is then used to calculate BMD; subsequently, it computes Z-scores and T-scores using patient age, gender, and a CT scanner-specific calibration factor, outputting these results along with images for radiologist review. Performance studies demonstrated a strong correlation between ABMD Software and manual QCT-based BMD measurements (r=0.97), and a modest but significant correlation with DXA scans (r=0.72), aligning with literature comparisons of manual QCT and DXA and highlighting its specificity for trabecular bone assessment.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Bone Mineral Density (BMD)CT ScansHounsfield Units (HU)Trabecular BoneAI-powered SoftwareVertebral BonesOpportunistic ScreeningPost-processingQuantitative Computed Tomography (QCT)Z-score / T-score

Device Metadata

Submission Number
K213760
Company
HeartLung Corporation
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the AI model's performance in vertebral bone segmentation vary across different CT scanner manufacturers, models, and image acquisition protocols?; What is the range of CT scanner-specific calibration factors, and how sensitive are the final BMD, T-score, and Z-score outputs to variations or inaccuracies in these input calibration factors?; Given the software relies on existing CT scans, what are the minimum image quality or specific scan parameters (e.g., slice thickness, reconstruction kernel) required for reliable ABMD measurements?; How does the software's performance compare to manual QCT when vertebral pathologies (e.g., fractures, metastases, degenerative changes) are present within the analyzed segments?; What is the clinical impact of the 'modest' correlation (r=0.72) with DXA, particularly in terms of diagnostic concordance for conditions like osteoporosis or osteopenia when using ABMD Software as an opportunistic tool?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score0/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials
- Not detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, ML-BOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
ABMD Software - HeartLung Corporation | ESL FDA AI Device Intelligence