Eko Murmur Analysis Software (EMAS)
Eko Devices, Inc. • Cardiovascular • 06/29/2022
Device Purpose
The Eko Murmur Analysis Software (EMAS) is a cloud-based system utilizing machine learning and signal processing to analyze heart sounds from digital stethoscopes, providing clinicians with decision support for identifying and classifying heart murmurs. Its methodology involves API-driven data submission, algorithmic detection of S1/S2 sounds, murmur presence, character (innocent vs. structural), and timing, aiming to enhance the evaluation of heart health in pediatric and adult patients.
Summary
The Eko Murmur Analysis Software (EMAS) is a cloud-based clinical decision support tool designed to assist clinicians in evaluating patient heart sounds. It analyzes phonocardiogram (PCG) and optional electrocardiogram (ECG) data, acquired via Eko DUO or Eko CORE digital stethoscopes and transmitted through an application programming interface (API). The software employs signal processing techniques and machine learning algorithms to assess PCG signal quality, detect the presence and timing of S1 and S2 heart sounds, and identify systole and diastole regions. A key function of EMAS is its ability to detect heart murmurs, classify them as either innocent (non-pathologic) or structural (pathologic), and determine their timing within the cardiac cycle. The system outputs results in a JSON format for display on a user's application, intended for use by clinicians on both pediatric and adult patients as an adjunct to their clinical judgment, not as a standalone diagnostic tool. The performance of EMAS was validated through a retrospective clinical study on a proprietary database of 2,380 heart sound recordings from 615 unique subjects (age 0-95 years), collected using Eko CORE and Eko DUO digital stethoscopes. Ground truth was established via cardiologist annotations paired with echocardiograms. In murmur classification, EMAS achieved 85.6% sensitivity (95% CI: 82.6-88.7) and 84.4% specificity (95% CI: 81.3-87.5); the clinical validation demonstrated that the lower bounds of these 95% confidence intervals were above 75.0%, indicating its effectiveness relative to established benchmarks. For heart sound timing, S1 detection showed 96.2% sensitivity and 97.1% PPV, while S2 detection achieved 92.3% sensitivity and 94.3% PPV. No adverse events occurred during the study, supporting the software's capability for effective heart sound analysis.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the algorithm's performance in murmur classification vary across different age groups, particularly between neonatal, pediatric, and adult populations, given the diverse age range (0-95 years) in the validation study?; What specific machine learning models and features derived from the PCG/ECG signals are most critical for the accurate distinction between innocent and structural murmurs?; Given the predominantly white (98% of the 45% where race was recorded) validation cohort, what steps are planned to validate or adapt the EMAS algorithms for more racially diverse populations to ensure equitable performance?; How does the Signal Quality Detection Algorithm handle common sources of interference in clinical settings (e.g., patient movement, ambient noise, poor stethoscope placement), and what is the impact of 'poor' signal quality classification on subsequent murmur analysis?; What is the typical processing time for a recording from data upload via the API to the return of the JSON analysis results, and how might this vary with ECG data inclusion or signal complexity?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.