Medscape Medical NewsAll articles

LiverMultiScan v5 (LMSv5)

Perspectum • Radiology • 09/06/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

LiverMultiScan v5 is a post-processing software application that analyzes magnetic resonance images to non-invasively quantify liver tissue characteristics, specifically Proton Density Fat Fraction (PDFF), T2*, Liver Iron Concentration (LIC), and iron-corrected T1 (cT1). It employs automated segmentation, region of interest analysis, and parametric mapping with artefact detection to produce a quantitative report aiding clinicians in liver assessment.

Summary

LiverMultiScan v5 (LMSv5) is a standalone software device designed for the non-invasive evaluation of liver tissue characteristics by post-processing Magnetic Resonance (MR) images. It utilizes DICOM 3.0 compliant MR image datasets from compatible systems to generate, display, and review 2D medical images and pixel maps representing MR relaxation times. The software includes tools such as automated liver segmentation leveraging machine-learning, region of interest (ROI) placement, and automatic artefact detection to assist a trained operator in quantifying metrics from parametric maps. The primary purpose is to provide quantitative assessment, and a summary report is generated for interpretation by a clinician as an aid to diagnosis, without replacing established clinical procedures or making direct diagnostic decisions. LMSv5 quantifies several key liver metrics: triglyceride fat fraction (Proton Density Fat Fraction, PDFF), T2*, Liver Iron Concentration (LIC), and iron-corrected T1 (cT1). PDFF is quantified using the LMS IDEAL method, while LIC is derived from measured T2* values transformed by a calibration curve. The cT1 map is generated by correcting T1 measurements for the effects of elevated iron and standardizing for fat signals. The software visualizes these metrics through parametric maps and allows for quantification via full liver segmentation or manual ROI placement, reporting median and interquartile range (IQR) metrics. It is intended to provide additional information to clinicians as part of a comprehensive diagnostic process for patients presenting with symptoms or risk factors of liver disease.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

LiverMultiScan v5Magnetic Resonance ImagingLiver EvaluationParametric MapsPDFFT2*Liver Iron Concentration (LIC)Iron Corrected T1 (cT1)Automated Liver SegmentationArtefact Detection

Device Metadata

Submission Number
K213960
Company
Perspectum
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. What is the accuracy and reproducibility of the Liver Iron Concentration (LIC) derived from T2* values compared to direct R2-based methods or liver biopsy, especially at varying levels of iron overload?; How does the machine-learning based automatic liver segmentation perform in patients with atypical liver morphology or extensive focal lesions, and what is the typical operator intervention rate?; Can the system differentiate between various causes of elevated cT1 values beyond iron and fat, and what is its sensitivity to subtle fibrotic changes?; What is the impact of MR scanner field strength and vendor variations on the quantitative metrics (PDFF, T2*, LIC, cT1), and what specific calibration or normalization steps are implemented in LMSv5 to ensure consistency?; How does the automatic artefact detection feature influence the selection of image slices for quantification, and what is its performance in identifying clinically significant artefacts that could alter diagnostic interpretation?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
LiverMultiScan v5 (LMSv5) - Perspectum | ESL FDA AI Device Intelligence