Medscape Medical NewsAll articles

CogNet QmTRIAGE

MedCognetics, Inc. • Radiology • 09/29/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

CogNet QmTRIAGE is a software as a medical device that utilizes a machine learning algorithm to analyze 2D FFDM screening mammograms for suspicious findings, aiming to assist radiologists by prioritizing their worklist. Its methodology involves passive notification of flagged exams to a PACS/workstation, enhancing triage efficiency without altering the standard diagnostic pathway or providing diagnostic information.

Summary

CogNet QmTRIAGE is a software tool designed to assist MQSA qualified interpreting physicians in managing their workflow for 2D Full-Field Digital Mammography (FFDM) screening exams. It employs an artificial intelligence algorithm to analyze these mammograms at the exam level, identifying and flagging studies that exhibit findings suggestive of potential cancer. This process operates in a parallel workflow, meaning it doesn't interfere with the standard review process or remove any exams from the physician's worklist; instead, it provides a passive notification to a PACS or workstation, allowing for the prioritization of exams deemed suspicious. The system is specifically intended for triage and prioritization purposes only and does not offer diagnostic information, nor should it replace a full patient evaluation or be used to confirm a diagnosis. The AI algorithm was trained on diverse global datasets, independent of the testing data. The performance of CogNet QmTRIAGE was validated using a retrospective cohort of 800 anonymized 2D FFDM mammograms, sourced from the USA and Germany, which included 399 biopsy-confirmed cancer cases and 401 negative cases with two-year follow-up. The validation study demonstrated strong performance metrics, achieving an overall Area Under the Receiver Operating Characteristic curve (AUROC) of 0.9569. Furthermore, the software achieved an overall sensitivity of 87% and a specificity of 89% across the entire test dataset, values that reportedly exceed the standard of care benchmarks from the Breast Cancer Surveillance Consortium study. The study considered various confounding factors such as lesion type, breast density, age, and race, and utilized images from multiple FFDM system vendors, with Hologic Selenia Dimension specified for the initial release.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Artificial IntelligenceMammographyTriageWorklist Prioritization2D FFDMRadiology SoftwareSuspicious FindingsSoftware as a Medical DevicePACSMachine Learning

Device Metadata

Submission Number
K220080
Company
MedCognetics, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. How does the algorithm's performance (sensitivity/specificity) vary across different breast density categories and specific lesion types (e.g., microcalcifications vs. soft tissue masses)?; What were the specific characteristics of the training dataset (e.g., size, geographic distribution beyond "worldwide", cancer prevalence, vendor distribution) and how might these influence generalizability to diverse patient populations and imaging equipment not heavily represented?; The document mentions the exclusion of BI-RADS 0 cases that were determined to be benign after diagnostic workup from the test set; how would the inclusion of such cases, which often require further investigation, impact the software's real-world triage effectiveness and false positive notification rate?; Beyond the Hologic Selenia Dimension, what is the anticipated timeline or validation process for extending compatibility and ensuring consistent performance with other FFDM systems from vendors like GE, Siemens, and Fujifilm mentioned in the performance study?; Could the prioritization feature inadvertently lead to increased radiologist fatigue or bias if a high volume of cases are flagged, and are there any studies planned to assess its long-term impact on radiologist reading times and diagnostic accuracy for non-prioritized cases?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score40/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, machine learning, algorithm, dataset, test set)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
CogNet QmTRIAGE - MedCognetics, Inc. | ESL FDA AI Device Intelligence