Rayvolve
AZmed SAS • Radiology • 06/02/2022
Device Purpose
Rayvolve is a standalone software utilizing supervised deep learning algorithms, trained on a diverse international dataset of osteoarticular radiographs, to assist clinicians in the detection and localization of fractures in adult patients. Its methodology involves processing DICOM X-ray images to provide diagnostic aid, aiming to enhance fracture detection accuracy as demonstrated by improved reader performance in clinical studies.
Summary
Rayvolve is a standalone software medical device designed to assist radiologists and emergency physicians in detecting and localizing fractures on osteoarticular X-rays for adult patients aged 22 years and older. It employs deep learning techniques, developed using a diverse dataset of labeled radiographs from multiple international centers, to analyze DICOM images from various anatomical regions including the ankle, clavicle, elbow, forearm, hip, humerus, knee, pelvis, shoulder, tibia/fibula, wrist, hand, and foot across frontal, lateral, oblique, and axillary views. The software integrates with Picture Archiving and Communication System (PACS) servers, processing DICOM files to output predictions on the potential presence or absence of fractures, and is intended as an adjunctive tool, not a replacement for medical professionals. Performance data for Rayvolve includes both standalone assessments and a multiple-reader, multiple-case (MRMC) clinical study. Standalone testing on 2626 radiographs demonstrated high sensitivity (0.98763), specificity (0.88558), and an Area Under the Curve (AUC) of 0.98607, with consistent performance across different anatomical areas, patient demographics, and X-ray machine manufacturers. The MRMC study, involving 24 clinical readers and 186 cases, showed that Rayvolve-aided readings significantly improved diagnostic accuracy (AUC increased from 0.84602 to 0.89327), sensitivity (from 0.86561 to 0.9554), and specificity (from 0.82645 to 0.83116) compared to unaided readings in detecting fractures.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does Rayvolve's deep learning model architecture specifically address the variability in fracture presentation across different anatomical regions and X-ray views?; What were the specific criteria for labeling radiographs in the training dataset, and how was inter-rater reliability ensured among labellers from diverse international centers?; Beyond the listed AUC, sensitivity, and specificity, what is the software's performance on subtle or hairline fractures, which are often challenging to detect?; How does the software handle images with significant artifacts or poor image quality, and what is the false positive rate in such scenarios?; The MRMC study showed improved reader performance; what was the average time difference for radiologists to interpret cases with versus without Rayvolve assistance, and how does this impact clinical workflow?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.