Medscape Medical NewsAll articles

TeraRecon Neuro

TeraRecon, Inc • Radiology • 08/12/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

TeraRecon Neuro is an advanced image processing software that analyzes dynamic CT and MRI brain perfusion datasets to generate quantitative parametric maps and visualizations, including Tmax, mismatch, and hypoperfusion maps. Its purpose is to provide clinicians with tools for enhanced diagnosis, clinical decision support, treatment planning, and post-treatment evaluation in neurological conditions by offering detailed insights into brain tissue perfusion and vascular status.

Summary

TeraRecon Neuro version 2.0.0 is an image processing software device designed for the analysis of dynamic brain perfusion image data acquired via CT or MRI. It performs motion correction and calculates various parameters related to brain tissue perfusion, vascular assessment, and tissue blood volume. The software outputs include parametric maps such as time to peak (TTP), mean transit time (MTT), blood volume (BV), blood flow (BF), and newly added maps for CT modality: time to maximum (Tmax), hypoperfusion maps, and mismatch (penumbra/umbra) maps with associated volumes and ratios. It also provides 2D and 3D visualizations of brain tissues and blood vessels, including a 'tumble view' for qualitative review of vascular structures in correlation to perfusion maps. The TeraRecon Neuro algorithm is intended for use by trained healthcare professionals, including physicians and surgeons, to aid in diagnosis, clinical decision support, treatment planning, and post-treatment evaluation. It can be deployed as a Microsoft Windows executable or a containerized application on off-the-shelf hardware or cloud platforms. The results can be viewed through systems like TeraRecon's Intuition or Eureka, or other DICOM-compliant viewers. The software is an update to the predicate Neuro.AI Algorithm (K200750), with key enhancements being the addition of Tmax, hypoperfusion, and mismatch maps, alongside improvements to existing perfusion map quality. Performance was validated through software testing, quantitative phantom testing, and qualitative clinical user evaluation against predicate and reference devices.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Brain perfusionImage processing softwareCTMRIParametric mapsTmaxMismatch mapsHypoperfusion mapsClinical decision supportNeuroimaging

Device Metadata

Submission Number
K220349
Company
TeraRecon, Inc
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the motion correction algorithm in TeraRecon Neuro version 2.0.0 compare in accuracy and processing time to other standard motion correction techniques for dynamic brain imaging?; What are the specific algorithms or mathematical models underpinning the calculation of the newly added perfusion maps (Tmax, Hypoperfusion, Mismatch), and how were they validated beyond qualitative comparison with reference devices?; What is the typical processing time for a standard CT or MRI brain perfusion dataset using TeraRecon Neuro, and how does this scale with dataset size or complexity?; Are there any known limitations or contraindications for using TeraRecon Neuro with specific patient populations (e.g., pediatric, patients with severe motion artifacts) or in the presence of particular imaging artifacts not fully corrected by the software?; Beyond the qualitative assessment and Tmax quantitative evaluation against reference devices, what further studies are planned to assess the impact of TeraRecon Neuro on diagnostic accuracy, inter-rater reliability, or clinical outcomes for specific neurological conditions like acute ischemic stroke?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score20/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cloud, platform)
✓ Detected
HBOMHardware Bill of Materials(hardware)
✓ Detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(container)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, HBOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
TeraRecon Neuro - TeraRecon, Inc | ESL FDA AI Device Intelligence