Medscape Medical NewsAll articles

SwiftMR

AIRS Medical Inc. • Radiology • 05/25/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

SwiftMR is a medical image processing software that employs distinct deep learning algorithms for denoising and an adjustable sharpening filter to enhance non-contrast MR images of the brain, spine, and musculoskeletal system. Its methodology involves automated DICOM image processing, from reception through enhancement (improving SNR and sharpness) to PACS transmission, aiming to improve image quality for radiological assessment.

Summary

SwiftMR is a Software as a Medical Device (SaMD) designed to enhance Magnetic Resonance (MR) images by reducing noise and increasing sharpness. Its core methodology involves using deep learning algorithms for denoising and a separate, adjustable sharpening filter for improving image clarity. The system processes standard DICOM MR images, operating automatically in the background. It features four distinct deep learning algorithms: three tailored for general pulse sequences from different MRI manufacturers and one specifically for Time-of-Flight (TOF) pulse sequences. These algorithms share a common network architecture but are trained on distinct datasets. The enhanced DICOM images are then transferred to a Picture Archiving and Communication System (PACS). The device is intended for professional use by radiology technologists in settings such as imaging centers, clinics, or hospitals, and is not for mobile device use. SwiftMR supports non-contrast enhanced MR images of the brain, spine, knee, ankle, shoulder, and hip, accommodating various imaging protocols (e.g., T1, T2, FLAIR, PD, TOF). Performance validation demonstrated that SwiftMR increases the signal-to-noise ratio (SNR) by 40% or more for noise reduction. For sharpness, it achieved a quantifiable decrease in Full Width at Half Maximum (FWHM) across five adjustable levels (from 0.43% at level 1 to 4.5% at level 5) in at least 90% of the tested dataset, which included images from major MRI manufacturers (SIEMENS, GE, PHILIPS) and different field strengths (1.5T/3.0T).

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

SwiftMRMRI enhancementDeep learningDenoisingImage sharpeningDICOMPACS integrationRadiology softwareSignal-to-Noise Ratio (SNR)Medical image processing

Device Metadata

Submission Number
K220416
Company
AIRS Medical Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Generation
AI Subclass
image enhancement

Relevant Clinical Questions

  • Q1. How does the performance of the three general sequence deep learning models, segmented by MRI manufacturer, compare both to each other and to a single, generalized model approach?; What is the clinical impact of the adjustable sharpening filter (levels 0-5) on diagnostic confidence or interpretation time across different anatomical regions (brain, spine, MSK) and common pathologies?; Are there specific MRI sequences or patient demographic factors where SwiftMR's enhancement (denoising and sharpening) provides a demonstrably more significant improvement in perceived image quality or diagnostic utility?; How does SwiftMR's algorithm handle images with pre-existing artifacts (e.g., motion, susceptibility) and is there a risk of artifact amplification or misinterpretation post-processing?; What are the typical processing times per image series for the supported anatomical regions, and how does the system's background operation integrate with varying clinical throughput demands without causing workflow bottlenecks?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
SwiftMR - AIRS Medical Inc. | ESL FDA AI Device Intelligence