Neurophet AQUA
NEUROPHET, Inc. • Radiology • 05/10/2023
Device Purpose
Neurophet AQUA is an advanced medical software that automates the volumetric analysis of brain structures from T1-weighted MR images using a deep learning-based segmentation pipeline. Its purpose is to provide clinicians and researchers with quantitative morphometric data and comparisons to normative references, thereby supporting the assessment of brain MRIs in clinical and research settings.
Summary
Neurophet AQUA is a medical image processing software designed for the automated analysis of brain Magnetic Resonance (MR) images. Its core function is to perform automatic labeling, visualization, and volumetric quantification of segmentable brain structures derived from T1-weighted MRI series. The software employs a proprietary internal pipeline powered by deep learning algorithms for precise segmentation, followed by volume calculation and the generation of detailed morphometric reports. These reports can include comparisons of an individual's brain structure volumes against age and gender-matched reference percentile data, offering a quantitative basis for neurological assessment. The outputs, including color-coded segmented images and comprehensive morphometric reports, are compatible with Picture Archive and Communications Systems (PACS), facilitating integration into clinical workflows. Neurophet AQUA is intended as a supportive tool for clinicians in both routine patient care and clinical trial research for assessing structural MRIs. Performance evaluations have validated its methodology, showing segmentation accuracy (Dice coefficient) of 75-85% for major cortical regions and 80-90% for major subcortical structures compared to expert manual segmentations. Furthermore, its reproducibility on repeated scans for major subcortical structures demonstrated mean percentage absolute volume differences between 1-5%, underscoring its reliability in quantifying brain morphometry.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the deep learning model in Neurophet AQUA specifically address variability in MR image quality and artifacts, beyond general data augmentation techniques mentioned for the training dataset?; What is the specific composition, size, and demographic diversity of the 'reference healthy population' used for generating percentile data, and how does the software account for factors beyond age and gender?; Can the software differentiate between subtle pathological changes associated with early-stage neurodegenerative diseases and normal anatomical variations, given the reported Dice coefficients for segmentation accuracy?; What are the computational time requirements for processing a typical T1 MRI series from input to report generation, and how does this performance scale for high-throughput clinical environments?; Are there validation studies on the software's performance in longitudinal analysis, specifically its ability to reliably track volumetric changes in brain structures over time for individual patients and manage serial scan registration?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, OBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly