aPROMISE X

EXINI Diagnostics AB • Radiology • 04/29/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

aPROMISE X is a software platform intended for healthcare professionals and researchers to enhance the review, quantification, and reporting of PSMA PET/CT medical images in oncology. Its methodology centers on DICOM image management, machine-learning assisted hotspot detection for regions of interest, and user-validated automated quantitative analysis to improve consistency and efficiency in oncological assessments.

Summary

aPROMISE X is an updated software platform designed for healthcare professionals and researchers to manage and process digital medical images, specifically focusing on Prostate-Specific Membrane Antigen (PSMA) Positron Emission Tomography/Computed Tomography (PET/CT) scans for oncology. It functions as a medical image management and processing system, facilitating the acceptance, transfer, storage, display, manipulation, quantification, and reporting of these images. The system, accessible via a web interface, can be deployed on cloud infrastructure or a local server and supports the DICOM 3 standard for image data, allowing uploads via file selection or direct transmission from a Picture Archiving and Communication System (PACS). It presents studies in a 4-panel view (PET, CT, PET/CT fusion, and maximum intensity projection) and offers image visualization and analysis tools for users to identify and mark regions of interest. The core methodology involves users reviewing image data and marking regions of interest (ROIs) either by selecting from pre-defined hotspots, which are identified by a machine-learning algorithm detecting high local intensity areas in the PET series, or by manual voxel selection. These selected hotspots undergo automatic quantitative analysis, calculating metrics such as Standardized Uptake Values (SUV-max, SUV-mean, SUV-peak), volume, Lesion Index, and Intensity-weighted Tissue Lesion Volume. Users then review these quantitative results to determine which hotspots represent suspicious lesions for inclusion in electronically signed reports, exportable as JPG or DICOM files. Performance data from bench testing confirmed its accuracy and linearity using a digital phantom, equivalent performance to its predicate for marking and quantitative assessments, and an analytical study demonstrated that aPROMISE X enables more reproducible and efficient automated quantification of tracer uptake compared to manual methods, while maintaining physicians' diagnostic performance.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

PSMA PET/CTImage Analysis SoftwareDICOMQuantitative AnalysisRegion of Interest (ROI)Hotspot DetectionMachine LearningStandardized Uptake Value (SUV)Medical Image ManagementOncology

Device Metadata

Submission Number
K220590
Company
EXINI Diagnostics AB
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the machine-learning model for hotspot detection in aPROMISE X differ from the analytical model used in its predicate, and what specific improvements in sensitivity or specificity for lesion detection were observed in comparative studies?; What are the specific validation metrics from the 'Analytical Performance in Clinical Study' that quantify the increased reproducibility and efficiency of automated quantification with aPROMISE X compared to manual methods by clinicians?; Can aPROMISE X be customized or trained further with local institutional data to improve its hotspot detection or organ segmentation accuracy for specific patient populations or scanner protocols?; What are the computational requirements (e.g., processing time, memory) for aPROMISE X when handling large PSMA PET/CT datasets or multiple simultaneous users, particularly for the cloud-deployed configuration?; Beyond the listed SUV metrics and volume, are there plans to incorporate more advanced radiomic features or textural analysis within aPROMISE X for a more comprehensive characterization of identified lesions?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score15/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cloud, server, platform, infrastructure)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(configuration)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
aPROMISE X - EXINI Diagnostics AB | ESL FDA AI Device Intelligence