eMurmur Heart AI

CSD Labs GmbH • Cardiovascular • 05/31/2022

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

eMurmur Heart AI is a software-based decision support tool that utilizes an advanced algorithm to analyze digital heart sound recordings and patient age to assist clinicians in identifying and differentiating various heart sounds, including murmurs. Its methodology relies on processing 20-second auscultation data to detect S1/S2 sounds and classify murmurs as physiological, pathological, or absent, providing interpretations intended to augment, not replace, comprehensive clinical assessment.

Summary

The eMurmur Heart AI software serves as a decision support system for healthcare providers, designed to aid in the evaluation of recorded patient heart sounds. Its core function is the automated analysis of these sounds to identify S1 and S2 components, distinguish between physiological and pathological heart murmurs, and recognize the absence of a murmur. The system requires a 20-second digital recording of heart sounds, typically captured with a supported digital stethoscope such as the Littmann 3200, along with the patient's age. The analytical results are then presented on a front-end client, like the eMurmur app or web portal, for clinical review, emphasizing that the AI's interpretations should be used in conjunction with other patient information and professional medical judgment, not as a standalone diagnostic tool. The central technology of eMurmur Heart AI is its heart sound analysis algorithm, which is the regulated medical device component; the accompanying platform components (apps, web portal, backend for data handling) are considered non-medical device software. This algorithm is identical to the one used in a previous iteration, eMurmur ID, and therefore, eMurmur Heart AI shares the same established performance metrics for murmur detection: a sensitivity of 85.0% (Confidence Interval: 72.9% - 92.5%) and a specificity of 86.7% (Confidence Interval: 74.9% - 93.7%). The system processes auscultation data transmitted from the front-end client to the eMurmur backend, where the AI performs the analysis, and then returns the findings to the user to support their clinical decision-making process.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

eMurmur Heart AIHeart sound analysisDecision supportAuscultationDigital stethoscopeMurmur detectionPathological murmurPhysiological murmurSoftware algorithmCardiac acoustics

Device Metadata

Submission Number
K220766
Company
CSD Labs GmbH
Panel
Cardiovascular
Product Code
N/A
Data Type
Signals
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
diagnosis

Relevant Clinical Questions

  • Q1. What are the specific algorithmic features that enable the differentiation between physiological and pathological murmurs with the reported sensitivity of 85.0% and specificity of 86.7%?; How does the eMurmur Heart AI algorithm specifically utilize the patient's age, in conjunction with the 20-second heart sound recording, to improve analysis accuracy?; What validation was performed to ensure that the separation of the front-end/backend (non-medical device) from the AI algorithm (medical device) does not introduce risks to data integrity or analysis quality?; How does the system account for variations in recording quality stemming from different supported digital stethoscopes, user techniques, or ambient noise?; Can the performance metrics (sensitivity and specificity) be broken down for the individual identification of S1, S2, physiological murmurs, pathological murmurs, and the absence of murmurs, rather than just overall murmur detection?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(platform, backend)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly