Medscape Medical NewsAll articles

syngo.via RT Image Suite

Siemens Medical Solutions USA Inc. • Radiology • 09/07/2022

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

The syngo.via RT Image Suite is an advanced image analysis software designed to support radiation therapy planning by enabling comprehensive visualization, multi-modality manipulation, and precise segmentation of anatomical structures, including tumors and organs-at-risk. It leverages digital image processing techniques, incorporating AI-driven deep learning for functionalities such as automated lung lobe segmentation for ventilation assessment, to facilitate accurate contouring, image fusion, and the preparation of geometric treatment plans.

Summary

The syngo.via RT Image Suite, software version SOMARIS/8 VB70, is an image analysis software designed for radiation therapy planning. It enables viewing, manipulation, 3D/4D visualization, and comparison of medical images from multiple modalities (e.g., CT, PET, MRI, Linac CBCT). The software supports the segmentation of tumors and organs-at-risk through manual and software-assisted contouring tools, facilitates rigid and deformable image registration, and allows for the creation of simple geometric treatment plans which can be exported. Key modifications in this version include enhanced patient marking with simplified isocenter placement in the spine, a new tool for converting isodose lines to contours, improved contouring capabilities on 4D image data, the introduction of lobe-based lung ventilation, and an added software interface for advanced visualization and measurement tools. A significant feature of this software version is the AI-driven lobe-based lung ventilation calculation, which uses a deep learning algorithm for autosegmentation of lung lobes from inspiration and expiration CT images. The AI component, reused from a prior version, was trained on 8721 scans, validated on 969, and tested on an independent cohort of 18 radiotherapy patients, achieving a mean DICE coefficient of 0.92 for lung lobe segmentation. Clinical validation of the overall lung ventilation algorithm on 108 CT datasets from 74 patients demonstrated that ventilation distributions were comparable to literature-derived values in one subgroup (4D-CT, normal breathing). In another subgroup (breathhold CT, forced breathing), ventilation results showed a significant correlation (R=0.63, p<0.001) with spirometry-measured vital capacity. The document notes limitations, including reliance on literature for ground truth in one validation arm and potential discrepancies due to differing conditions between CT and spirometry tests, advising that the ventilation results should not be the sole diagnostic tool.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

syngo.via RT Image SuiteRadiation Therapy PlanningImage VisualizationContouringTumor Segmentation4D ImagingLung VentilationAI SegmentationDeep LearningMulti-modality Imaging

Device Metadata

Submission Number
K220783
Company
Siemens Medical Solutions USA Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Intervention
AI Function
Generation|Analysis
AI Subclass
quantification/feature localization|synthetic data generation

Relevant Clinical Questions

  • Q1. Regarding the AI-based lung lobe segmentation, what was the variability in DICE scores across the 18 test patients, and were there specific anatomical variations or image qualities that correlated with lower scores?; How does the performance of the lobe-based lung ventilation algorithm, particularly its correlation with spirometry (R=0.63), vary in patient populations with different underlying pulmonary pathologies or varying degrees of tumor involvement in the lungs?; The 'simplified workflow to place isocenters in the spine' is mentioned; could you elaborate on the specific changes made and any quantitative data demonstrating improvements in efficiency or accuracy for this task?; For the tool that converts isodose lines from a DICOM RT dose file to contours, what is the validation process for this feature, and how does it ensure accuracy, especially in regions with steep dose gradients or complex isodose shapes?; Considering the stated limitations of the clinical validation for lung ventilation, such as reliance on literature for ground truth and differing exam conditions, what strategies could be employed in future studies to provide more direct, patient-specific validation of this feature's accuracy and clinical utility?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence✓ Detected in Summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials(software version)
✓ Detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, dataset, ground truth)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SBOM, ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
syngo.via RT Image Suite - Siemens Medical Solutions USA Inc. | ESL FDA AI Device Intelligence