Medscape Medical NewsAll articles

Libby Echo:Prio

Dyad Medical, Inc • Radiology • 07/20/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Libby Echo:Prio is an advanced software tool designed to enhance the analysis of cardiovascular ultrasound images by utilizing machine learning for automated view classification, cardiac segmentation, and quantification of key parameters like ejection fraction. It aims to provide clinicians with accurate, consistent, and efficient data to support diagnostic decision-making in adult patients undergoing echocardiographic examinations.

Summary

Libby Echo:Prio, from Dyad Medical, Inc., is an image post-processing analysis software designed for viewing and quantifying cardiovascular ultrasound images from adult patients. Its primary purpose is to aid qualified healthcare practitioners, such as cardiologists and sonographers, in diagnostic review, analysis of echocardiographic data, patient record management, and reporting. The software processes previously acquired DICOM-compliant cardiac ultrasound images, allowing sonographers to perform necessary markups, including identifying cardiac segments and taking measurements of distance, time, and area. It supports both manual markup and leverages machine learning for automated view classification and border segmentation, which can be accepted, modified, or rejected by the user. The software provides functionalities for 2D image and cine loop review, and importantly, quantifies key cardiac parameters. These include echocardiographic view classification, identification of end-diastolic (ED) and end-systolic (ES) frames for heartbeat rate (HR) estimation, and calculation of ejection fraction (EF). Ejection fraction assessment is achieved through automatic segmentation of the left ventricle (LV) chamber endocardium, left atrium (LA), and LV myocardium (LVMC), allowing muscle thickness calculations. Performance testing demonstrated high accuracy, with view classification achieving 97% accuracy (F1 >96.6%, Sensitivity 96.8%, Specificity 98.5%), and heart rate estimates showing minimal bias (slope of 0.98) compared to 12-lead ECG. The automated ejection fraction prediction showed a strong correlation (slope of 0.79, 95% CI 0.52-0.98) with annotations by four human experts, within the range of typical inter-observer variability.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Cardiovascular ultrasoundEchocardiographyImage post-processingMachine learningEjection fractionAutomated segmentationCardiac measurementsDICOMClinical decision supportView classification

Device Metadata

Submission Number
K220956
Company
Dyad Medical, Inc
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the machine learning algorithm's performance for automated segmentation and view classification vary across different ultrasound machine vendors and image qualities?; What specific features or parameters beyond ejection fraction and heart rate can Libby Echo:Prio quantify, and what is the validation data for these additional measurements?; The performance data mentions comparison to "four human experts" for EF prediction; what was the specific protocol for these expert annotations and how was inter-expert variability managed or accounted for in the comparison?; How does the software handle challenging or atypical cardiac anatomies or pathologies, and are there known limitations in its automated analysis capabilities for such cases?; What is the typical processing time for a standard echocardiographic study using Libby Echo:Prio, and how does this integrate into existing clinical workflows for sonographers and cardiologists?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, bias, annotation)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Libby Echo:Prio - Dyad Medical, Inc | ESL FDA AI Device Intelligence