Medscape Medical NewsAll articles

Aquilion Precision (TSX-304A/4) V10.10 with AiCE

Canon Medical Systems Corporation • Radiology • 09/12/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The Aquilion Precision (TSX-304A/4) V10.10 with AiCE is an advanced computed tomography system designed for whole-body, ultra-high resolution imaging, utilizing a Deep Convolutional Neural Network (AiCE) and iterative reconstruction (FIRST) to enhance image quality, reduce noise, and improve spatial resolution across diverse clinical applications including cardiac and lung imaging. This technology aims to provide superior diagnostic images at potentially optimized radiation doses by intelligently differentiating anatomical structures from noise during the reconstruction process.

Summary

The Aquilion Precision (TSX-304A/4) V10.10 with AiCE is an ultra-high resolution, whole-body multi-slice helical CT scanner designed to acquire and display cross-sectional volumes for various diagnostic applications, including head, abdomen, pelvis, chest, cardiac, and extremities. It incorporates a 160-row, 0.25 mm detector and rapid scanning capabilities to capture detailed volume data sets. A key technological advancement is its AiCE (Advanced intelligent Clear-IQ Engine) feature, which utilizes Deep Convolutional Neural Network (DCNN) methods for image reconstruction. This DCNN-based approach is engineered to reduce image noise and enhance image quality by differentiating between anatomical structures and noise, aiming for fast, high-quality CT reconstructions, particularly for 1024x1024 high-resolution (HR) and super-high-resolution (SHR) images. The system also includes the FIRST iterative reconstruction algorithm for dose reduction and improved high-contrast spatial resolution. This version (V10.10) builds upon its predicate by expanding the application of AiCE to lung and cardiac imaging, in addition to the existing abdomen and pelvis applications, and enhances gantry tilt operability with AiCE. The AiCE algorithm was retrained for these new indications. Performance testing demonstrated AiCE's substantial equivalence to the predicate, with improvements in noise texture, making it more natural than FIRST and comparable to filtered backprojection. Quantitative studies confirmed significant high-contrast spatial resolution improvements (e.g., >10 lp/cm across AiCE regions) at equivalent or dose-neutral levels compared to conventional reconstruction methods. Clinical image reviews affirmed the diagnostic quality of images produced by the device across various anatomical regions, including low-dose chest scans and studies of diseased patients. The system also showed improved performance for lung cancer screening applications.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Computed Tomography (CT)AiCE (Advanced intelligent Clear-IQ Engine)Deep Convolutional Neural Network (DCNN)Image ReconstructionNoise ReductionSpatial ResolutionWhole Body ImagingCardiac ImagingLung ImagingIterative Reconstruction (FIRST)

Device Metadata

Submission Number
K220986
Company
Canon Medical Systems Corporation
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Generation
AI Subclass
image enhancement

Relevant Clinical Questions

  • Q1. How does the retraining of the AiCE DCNN for lung and cardiac applications specifically address the unique imaging challenges (e.g., motion artifacts, tissue density variations) in these anatomical regions compared to abdominal/pelvic imaging?; What is the quantitative impact of AiCE on low-contrast detectability in the newly added lung and cardiac applications, especially at reduced radiation doses, beyond the stated 'equivalent LCD'?; Could the 'more natural noise texture' achieved by AiCE compared to FIRST and MBIR translate to improved diagnostic confidence or reduced interpretation time for radiologists, and are there studies planned to assess this?; Given the significant improvement in high-contrast spatial resolution (e.g., 16.5 lp/cm for Body HR), what are the practical implications for visualizing finer anatomical details or smaller pathologies, particularly in challenging cases?; With the console now integrating the AiCE/FIRST processing (CCRS-003B), what are the improvements in workflow efficiency, reconstruction times, and data handling compared to the previous separate I-REC BOX system?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(neural network, algorithm, data set, retraining)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Aquilion Precision (TSX-304A/4) V10.10 with AiCE - Canon Medical Systems Corporation | ESL FDA AI Device Intelligence