Viz RV/LV

Viz.ai, Inc. • Radiology • 08/29/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The Viz RV/LV software device employs an artificial intelligence algorithm to analyze volumetric CTPA scans, automatically identifying and measuring the maximal diameters of the heart's right and left ventricles to calculate their ratio. It provides clinicians with annotated DICOM images and a summary report displaying these measurements, intended as an adjunctive tool rather than a standalone basis for clinical decision-making in the assessment of right ventricle enlargement.

Summary

The Viz RV/LV is a software-only medical device that utilizes a locked artificial intelligence machine learning (AI/ML) algorithm to analyze volumetric computed tomography pulmonary angiogram (CTPA) scans. Its primary function is to automatically identify the right and left ventricles of the heart, measure their maximal diameters, and report the ratio of these measurements. This assists clinicians, including radiologists, pulmonologists, and cardiologists, in the assessment of potential right ventricle enlargement. The software processes CTPA scans forwarded to Viz.ai’s Backend Server and is not intended for standalone diagnostic use, but rather as an adjunctive tool to support clinical assessment. Upon analysis, Viz RV/LV generates results in DICOM format, specifically an Annotated Image Series and an RV/LV Summary Report. The annotated images provide visual overlays on scan slices, highlighting maximum ventricular diameters and the interventricular septum. The summary report details these maximal diameters, their lengths, and the calculated RV/LV ratio. Clinical performance testing demonstrated a mean absolute error (MAE) of less than 7.2 mm when comparing the algorithm’s measurements to a ground truth established by trained radiologists. The device's performance was stratified across various parameters like clinical site, patient demographics, and scanner characteristics, based on studies with distinct training and pivotal datasets.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Artificial IntelligenceCTPAVentricular DiameterRV/LV RatioDICOMImage ProcessingCardiac ImagingAutomated MeasurementRight Ventricle EnlargementVolumetric Acquisition

Device Metadata

Submission Number
K221100
Company
Viz.ai, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the AI algorithm's performance in measuring ventricular diameters vary across different CT scanner manufacturers and models not included in the pivotal study?; What is the range of CTPA slice thicknesses for which the Viz RV/LV software maintains its stated accuracy (MAE < 7.2 mm)?; Are there specific patient populations or cardiac pathologies (e.g., congenital heart defects, significant cardiac remodeling) where the algorithm's accuracy in identifying ventricular boundaries might be compromised?; How does the processing time of the Viz RV/LV software scale with the size and resolution of the input CTPA dataset, and what are the typical processing times in a clinical workflow?; Beyond the RV/LV ratio and maximal diameters, does the software provide any additional quantitative metrics or qualitative assessments of ventricular morphology from the CTPA scans that could be clinically useful?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, dataset, ground truth)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server, backend)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Viz RV/LV - Viz.ai, Inc. | ESL FDA AI Device Intelligence