Rapid ICH

iSchemaView Inc. • Radiology • 09/12/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Rapid ICH is a software device utilizing an artificial intelligence algorithm to analyze non-enhanced head CT images for the detection and notification of suspected intracranial hemorrhages. Its purpose is to expedite clinical workflow by providing rapid notifications to radiologists, thereby enabling prioritization of potentially critical cases and significantly reducing the time to image assessment compared to standard care.

Summary

Rapid ICH is a radiological computer-aided triage and notification software designed for the analysis of non-enhanced head CT (NCCT) images. Its primary function is to assist hospital networks and trained radiologists in workflow triage by flagging and communicating suspected positive findings of various intracranial hemorrhages (ICH), including intraparenchymal (IPH), intraventricular (IVH), subarachnoid (SAH), and subdural (SDH) types. The system employs an artificial intelligence (AI) algorithm to analyze these images, identifying and highlighting cases with detected ICH. This process occurs on a server or standalone desktop application, operating in parallel with the standard image interpretation workflow. Users receive notifications for cases with suspected ICH, which include compressed preview images intended for informational and triage purposes only, not for direct diagnosis, and the device does not alter original medical images. The performance of Rapid ICH was evaluated in a retrospective, multicenter, multinational study involving 314 NCCT head images, demonstrating an overall sensitivity of 96.8% and specificity of 100% in identifying ICH, with an AUC of 0.98632. A significant clinical benefit is the reduction in time-to-notification, averaging 0.65 minutes with Rapid ICH compared to a standard care time-to-exam-open of 72.6 minutes. Performance was further detailed across various ICH subtypes, patient demographics (gender and age), hemorrhage volume (e.g., 100% sensitivity for volumes ≥ 5mL), CT slice thickness, and different CT scanner manufacturers and models, generally showing robust results. The software is intended to be used in conjunction with other patient information and professional judgment to assist with triage and prioritization of medical images, with notified radiologists responsible for viewing full images per standard care.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Intracranial Hemorrhage (ICH)Computed Tomography (CT)Artificial Intelligence (AI)Machine Learning (ML)Triage SoftwareRadiologyWorkflow PrioritizationNon-enhanced CT (NCCT)Image AnalysisNotification System

Device Metadata

Submission Number
K221456
Company
iSchemaView Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. How does the AI algorithm differentiate between the various specified ICH subtypes (IPH, IVH, SAH, SDH) with varying degrees of subtlety or co-occurrence?; What were the specific characteristics of the 'additional data for training and validation' used for this version compared to K193087, and how did this data impact the algorithm's performance, particularly for challenging or rare ICH presentations?; How does the system handle variations in CT image quality, noise levels, or artifacts from different scanners or protocols, and what is the minimum image quality required for reliable performance?; Beyond time-to-notification, has there been any investigation into the downstream impact on clinical decision-making, radiologist reading times for positive cases, or patient outcomes when Rapid ICH is integrated into a clinical workflow?; What are the performance limitations, if any, for detecting very small volume hemorrhages (e.g., below the 0.4 mL threshold mentioned in performance metrics) or hemorrhages in anatomically complex locations?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server, network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.