ElucidVivo A.3

Elucid Bioimaging Inc. • Radiology • 06/17/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

ElucidVivo A.3 is an image analysis software package that processes CT images of arterial vessels to provide clinicians with quantitative measurements of vessel structure and plaque composition, aiding in the stratification of patients with atherosclerosis. The system incorporates improved technological characteristics, including kVp calibration and the use of MOVAT stain for ground truth comparison, to enhance the accuracy of identifying plaque components like Lipid Rich Necrotic Core, matrix, and calcifications.

Summary

ElucidVivo A.3 is an image analysis software package designed for evaluating CT images of arterial vessels. Its primary purpose is to assist trained physicians in the stratification of patients with atherosclerosis by enabling the processing, review, analysis, communication, and media interchange of multi-dimensional digital images acquired from CT scanners. The software provides multi-dimensional visualization and tools for measuring and analyzing anatomy and pathology, including semi-automatic determination of contrasted lumen boundaries, stenosis measurements, lumen diameters, Hounsfield unit statistics, and vessel length. Clinicians can view highlighted vessels in 3D, rotatable curved MPR views, and cross-sections, with the ability to edit lumen boundaries. ElucidVivo A.3 is intended as a complementary tool to the standard of care and not for direct diagnosis or clinical recommendations. The ElucidVivo A.3 system represents an improvement over its predicate by enhancing measurement performance for Lipid Rich Necrotic Core (LRNC), matrix (MATX), and calcifications (CALC). This was achieved by incorporating considerations for different energy levels through kVp calibration for plaque component measurement and by adopting MOVAT stain, which offers superior fidelity for LRNC delineation compared to the H&E stain used previously. Performance data was established through software verification and validation, including testing with phantom and clinical images. The evaluation focused on calculations of anatomic structure (compared to manual measurements and assessing inter/intra-reader variability) and tissue characteristics (compared to histopathologic specimens as ground truth). Analytic performance metrics such as bias, slope, intercept, RMSE, and wSD were reported for various structural and compositional measurements, alongside a note on potential overestimation of stenosis by diameter in very small lumens.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

ElucidVivo A.3AtherosclerosisCT Image AnalysisPlaque CompositionLipid Rich Necrotic Core (LRNC)Stenosis MeasurementkVp CalibrationMOVAT StainHistopathology ValidationArterial Vessel Imaging

Device Metadata

Submission Number
K221463
Company
Elucid Bioimaging Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the kVp calibration algorithm in ElucidVivo A.3 account for variability in CT scanner manufacturers and protocols to ensure consistent plaque component measurements?; What is the quantitative improvement in LRNC, matrix, and calcification delineation when using MOVAT stain as ground truth compared to the previous H&E stain methodology, and how does this impact inter-observer variability in histopathological assessment?; Given the acknowledged limitation for stenosis by diameter in small lumens, what specific quantitative threshold or guidance does ElucidVivo A.3 provide for clinicians to switch to qualitative assessment or alternative metrics like %stenosis by area?; How were the phantom and clinical images selected for validation testing, and do these datasets represent a diverse range of atherosclerotic plaque morphologies and patient demographics?; What are the implications of the reported bias and RMSE values for measurements like lumen area and LRNC area on the potential for misclassification of atherosclerosis severity, and how are these uncertainties communicated to the clinician?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score35/100
SBOM Evidence✓ Detected in Summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials(software package)
✓ Detected
ML-BOMMachine Learning Bill of Materials(algorithm, dataset, ground truth, bias)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SBOM, ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
ElucidVivo A.3 - Elucid Bioimaging Inc. | ESL FDA AI Device Intelligence