Medscape Medical NewsAll articles

AVIEW Lung Nodule CAD

Coreline Soft Co.,Ltd. • Radiology • 02/24/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

AVIEW Lung Nodule CAD is a computer-aided detection software designed to improve radiologists' accuracy and efficiency in identifying pulmonary nodules on chest CT scans from asymptomatic individuals. It employs a Deep Convolutional Neural Network algorithm to automatically detect nodules between 3 and 20mm, functioning as an adjunctive second reader and integrating with existing radiology workflows.

Summary

AVIEW Lung Nodule CAD is a software tool designed to assist radiologists in detecting pulmonary nodules, ranging from 3 to 20mm in diameter, in chest CT images of asymptomatic individuals. The system employs a Deep Convolutional Neural Network (CNN) based algorithm, trained on chest CT data, to automatically identify these nodules. It operates in compliance with DICOM standards, allowing integration with Picture Archiving and Communication Systems (PACS), and provides a dedicated user interface for analyzing, identifying, storing, and transmitting quantitative data about the detected nodules. Intended as an adjunctive tool, it functions as a second reader after the radiologist's initial review, allowing clinicians to confirm or dismiss the CAD's findings. The device's performance was notably validated using non-contrast CT images, primarily acquired from Siemens SOMATOM series scanners, and it is designed to be used with the cleared AVIEW platform. The clinical efficacy of AVIEW Lung Nodule CAD was assessed through a multi-reader, multi-case retrospective study involving 151 chest CTs and eleven board-certified radiologists. This study demonstrated statistically significant improvements when radiologists used the AI tool: the area under the curve (AUC) for nodule detection increased from 0.73 (unaided) to 0.92 (aided), and sensitivity rose from 0.68 to 0.91. Furthermore, the rate of false positives per scan decreased from 0.48 to 0.28, and reading time was reduced with AI assistance. A separate standalone performance evaluation on 282 datasets yielded an AUC of 0.961, sensitivity of 0.907, and specificity of 0.704, with a sensitivity of 0.889 at a false positive rate of 0.504 per scan, indicating robust standalone algorithmic performance.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

AVIEW Lung Nodule CADPulmonary NodulesChest CTDeep LearningComputer-Aided Detection (CAD)RadiologyDICOMAsymptomatic ScreeningAlgorithm PerformanceSecond Reader

Device Metadata

Submission Number
K221592
Company
Coreline Soft Co.,Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection

Relevant Clinical Questions

  • Q1. How does the AVIEW Lung Nodule CAD's performance compare on CT images acquired with different reconstruction kernels (smooth, medium, sharp) beyond the listed typical examples, and is there an optimal kernel setting for maximal detection efficacy?; The documentation states performance validation on Siemens SOMATOM CT scanners. What are the specific performance metrics or expected variability when using images from other CT manufacturers or models, particularly those with different noise profiles or image reconstruction algorithms?; Can the system differentiate between various types of pulmonary nodules (e.g., solid, subsolid, ground-glass opacity) within the 3-20mm range, and does its sensitivity or specificity vary significantly across these nodule types?; The reader study showed a decrease in false positives per scan with AI assistance. What are the common characteristics of false positives generated by the AI, and how does the system address potential confounders like scarring or vascular structures?; How does the integration with the AVIEW platform enhance the workflow beyond nodule detection, and are there plans to incorporate nodule characterization or risk stratification features directly within the CAD module?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, neural network, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network, platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
AVIEW Lung Nodule CAD - Coreline Soft Co.,Ltd. | ESL FDA AI Device Intelligence