Annalise Enterprise CXR Triage Trauma
Annalise-AI Pty Ltd • Radiology • 03/28/2023
Device Purpose
Annalise Enterprise CXR Triage Trauma is an artificial intelligence software tool that utilizes a deep-learning convolutional neural network to analyze adult chest X-rays for pleural effusion and pneumoperitoneum, aiming to prioritize these studies in clinical worklists. The device integrates with existing hospital information systems (PACS/RIS) and has demonstrated high sensitivity and specificity in identifying these critical findings, thereby facilitating expedited radiological review.
Summary
Annalise Enterprise CXR Triage Trauma is an AI-driven software tool designed to assist clinicians in prioritizing adult chest X-ray (CXR) studies by analyzing them for features suggestive of pleural effusion and pneumoperitoneum. It integrates with existing Picture Archiving and Communication Systems (PACS) or Radiology Information Systems (RIS) to flag these cases for earlier review in the worklist, employing a convolutional neural network trained on diverse international datasets to identify these specific findings; the system operates in parallel with standard clinical workflows, aiming to enhance triage efficiency without altering existing case priorities or serving as a standalone diagnostic tool. The core technology's performance was validated through a standalone study on 1269 CXR cases, independent of its training data and benchmarked against US board-certified radiologists, which demonstrated high diagnostic accuracy with an Area Under the Curve (AUC) of 0.980 for pleural effusion and 0.969 for pneumoperitoneum. Specific operating points showed high sensitivity and specificity for both conditions (e.g., pleural effusion: 96.0% sensitivity, 88.3% specificity; pneumoperitoneum: 90.1% sensitivity, 87.4% specificity), and the device achieved an average triage turn-around time under 30 seconds, though performance limitations are noted for prone positioning, unilateral left-sided pneumoperitoneum, and pleural effusion cases with scarring or pleural thickening.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the algorithm's performance vary with different severities or subtle presentations of pleural effusion and pneumoperitoneum?; What specific image preprocessing steps are employed by the AI before analysis, and how do these impact its robustness to variations in image quality or acquisition parameters?; Given the stated limitation for unilateral left-sided pneumoperitoneum, what is the proposed strategy or future development plan to improve its detection accuracy for this specific presentation?; How does the device's performance compare when using CXRs from portable versus fixed X-ray units, considering potential differences in image quality and patient positioning challenges?; What is the false positive notification rate in a real-world clinical setting, and what are the most common benign findings that trigger false alerts for pleural effusion or pneumoperitoneum?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly