Medscape Medical NewsAll articles

AIBOLIT 3D+

Aibolit Technologies, LLC • Radiology • 01/12/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Aibolit 3D+ is a medical image management and processing system designed to enhance surgical planning and intraoperative decision-making by converting CT and MRI DICOM images into interactive 3D anatomical models. Its methodology relies on sophisticated image processing, including radiologist-controlled, AI-assisted organ segmentation and 3D reconstruction, validated for accuracy in representing anatomical structures.

Summary

Aibolit 3D+ is a software-based medical imaging system designed to assist healthcare professionals in preoperative surgical planning, training, patient education, and intraoperative guidance. It processes multi-dimensional digital images acquired from CT and, critically with this update, MR imaging devices, converting DICOM files into interactive 2D and 3D anatomical models. The system allows users to manipulate these models, offering features like multi-axis rotation, transparent viewing of internal structures such as ducts, vessels, lesions, and calcifications, and differential coloration for highlighting specific anatomical regions. The workflow involves physicians uploading images and specifying areas of interest, followed by radiologist-led annotation and segmentation, optionally assisted by AI/machine learning, before the 3D model is generated for review and use. The core science involves advanced image processing algorithms for organ segmentation and 3D model reconstruction. For image segmentation, Aibolit 3D+ incorporates an optional artificial intelligence component based on machine learning, trained on a dataset of 108 anatomical structures from MRI scans; this AI-assisted segmentation is reviewed and controlled by a radiologist. Performance testing, including software verification and validation, demonstrated the system's intended use. Specific tests validated the segmentation software, assessed the repeatability and reproducibility of segmenting various anatomical structures, and confirmed the accuracy of 3D model generation. Further validation, particularly for the newly added MRI image processing capabilities, confirmed the conservation of shape dimensions and volume against a "ground truth" standard across multiple organ structures, radiologists, and viewing perspectives.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Medical Imaging Software3D ReconstructionSurgical PlanningCT ImagesMRI ImagesDICOMOrgan SegmentationImage ProcessingArtificial Intelligence (AI)Anatomical Visualization

Device Metadata

Submission Number
K222458
Company
Aibolit Technologies, LLC
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Intervention
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the AI-assisted segmentation algorithm's performance compare to manual segmentation by experienced radiologists in terms of accuracy and time efficiency for complex anatomical structures derived from MRI?; What is the specific "ground truth" standard used for validating the conservation of shape dimensions and volume, and how was its accuracy established?; What are the limitations of the software in processing images with significant artifacts or from patients with highly atypical anatomy?; How does the system ensure data integrity and security, particularly when handling sensitive patient DICOM data through its web-based platform and during AI processing?; What quantitative metrics were used to assess the accuracy of the 3D model generation for various organ structures, and what were the acceptable thresholds for these metrics?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, dataset, ground truth, annotation)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.