Medscape Medical NewsAll articles

Ceevra Reveal 3

Ceevra, Inc. • Radiology • 04/25/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Ceevra Reveal 3 is a medical imaging system that processes CT and MR scans to create interactive 3D visualizations for preoperative surgical planning and intraoperative display. It employs machine learning and computer vision algorithms to generate preliminary segmentations of normal anatomy in adult patients, with performance validated by quantitative metrics against expert segmentations across diverse datasets.

Summary

Ceevra Reveal 3 is a software-based medical imaging system designed to enhance surgical planning and intraoperative visualization. Its primary function is to process multi-dimensional digital images acquired from CT or MR scans, allowing for comprehensive review, analysis, communication, and media interchange. The system facilitates the generation of three-dimensional (3D) images from patient scans, which clinicians can view and interact with via dedicated mobile and desktop applications, or on external displays including virtual reality (VR) headsets. Key interactive features include rotating, zooming, panning, and selectively displaying or hiding individual anatomical structures. Ceevra Reveal 3 is intended for use by healthcare professionals to assist in preoperative surgical planning and for the intraoperative display of these 3D images, supporting clinicians in making final patient management decisions. A core component of Ceevra Reveal 3 is its use of machine learning and computer vision algorithms to generate preliminary segmentations of normal anatomy, specifically for adult patients aged 22 and over; for younger or unknown-age patients, 3D images are created without employing these machine learning algorithms. The system incorporates four distinct machine learning models, which were verified using a dataset of 141 actual CT or MR imaging studies, ensuring independence between training and testing data at the institutional level. Performance evaluation focused on diverse patient demographics and various scanner manufacturers. The accuracy of the ML-generated segmentations was quantified by comparing them against segmentations performed by medical professionals, using metrics such as the Sørensen–Dice coefficient (DSC) and the Hausdorff distance at the 95th percentile (HD-95). Reported DSC values for structures like prostate, bladder, kidney, arteries, and veins ranged from 0.81 to 0.90, while neurovascular bundles showed a 7.8 mm HD-95.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Medical Imaging3D VisualizationSurgical PlanningMachine LearningImage SegmentationCT ScanMR ImagingPreoperative SoftwareIntraoperative DisplayAnatomical Segmentation

Device Metadata

Submission Number
K222676
Company
Ceevra, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Intervention
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the performance of the machine learning segmentation, as indicated by DSC and HD-95 values, correlate with improvements in surgical planning efficiency or clinical outcomes?; What are the specific anatomical structures, beyond those listed with performance metrics, that Ceevra Reveal 3 can segment using its machine learning models, and what is their validated accuracy?; How is the 'preliminary' nature of the ML-generated segmentations communicated to clinicians to ensure they maintain final decision-making authority, and what is the typical workflow for reviewing and potentially modifying these segmentations?; What are the computational resource requirements and average processing times for generating 3D models from CT/MR scans, both with and without the machine learning algorithms, particularly for complex anatomical regions?; Considering the age restriction (22+ years) for machine learning algorithm use, what are the primary differences in the 3D image generation process and resulting visualization quality for pediatric patients or those of unknown age, and are there plans to validate the ML models for younger populations?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Ceevra Reveal 3 - Ceevra, Inc. | ESL FDA AI Device Intelligence