Aidoc Medical, Ltd. • Radiology • 12/05/2022

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

BriefCase is an AI-powered software designed to analyze chest and abdominal CT images for the detection of suspected Vertebral Compression Fractures, aiming to improve radiology workflow triage. It operates by processing DICOM images through a cloud-based algorithm and notifying clinicians of potential positive cases via a desktop application, demonstrating high sensitivity and AUC in performance studies.

Summary

BriefCase, developed by Aidoc Medical, Ltd., is a radiological computer-aided triage and notification software designed to analyze chest and abdominal CT images. Its purpose is to assist hospital networks and trained medical specialists in the bone health setting by improving workflow triage through the flagging and communication of suspected positive cases of Vertebral Compression Fractures (VCFx). The system employs an artificial intelligence algorithm and consists of three modules: an Aidoc Hospital Server for image acquisition, an Aidoc Cloud Server for image processing, and an Aidoc Desktop Application for workflow integration, which displays a feed of suspect cases. DICOM images are acquired, filtered, de-identified, and processed chronologically. Upon detecting a potential VCFx, the system notifies users with a compressed, low-quality, unannotated preview image intended solely for prioritization and explicitly not for diagnostic use, operating in parallel with standard image interpretation workflows without altering original images or the standard reading queue. The performance of BriefCase was assessed in a retrospective, blinded, multicenter study involving 318 cases from five U.S. clinical sites, with ground truth determined by three senior board-certified radiologists. The primary endpoint, the area under the receiver operating characteristic curve (AUC), was 97.6%, surpassing the pre-specified goal of >0.95. The software achieved a sensitivity of 95.11% and a specificity of 93.28% for VCFx detection. Secondary metrics included a mean time-to-notification of 117.2 seconds for true positive cases. Additional reported values were a Positive Predictive Value (PPV) of 55.2% and a Negative Predictive Value (NPV) of 99.5%. The study cohort had a mean age of 65.7 years, comprised 46.5% males and 53.5% females, and involved CT scans from various major manufacturers.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

BriefCaseVertebral Compression Fractures (VCFx)Artificial Intelligence (AI)CT imagesTriage softwareNotification systemRadiology workflowImage analysisAUC (Area Under Curve)DICOM

Device Metadata

Submission Number
K222692
Company
Aidoc Medical, Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. How does the algorithm's performance (sensitivity, specificity, AUC) vary across different CT scanner manufacturers and imaging protocols?; What specific features or image characteristics does the AI algorithm primarily rely on to identify suspected Vertebral Compression Fractures?; Given the PPV of 55.2%, what is the anticipated impact on radiologist workload in terms of reviewing flagged cases that are ultimately negative, and are there strategies to optimize this?; How does the time-to-notification of BriefCase (117.2 seconds) compare to the actual time saved in clinical practice for initiating VCFx patient management, considering the entire workflow?; What were the inclusion and exclusion criteria for the 318 cases in the pivotal study, and how might selection bias influence the reported performance metrics?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm, ground truth, bias)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cloud, server, network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
BriefCase - Aidoc Medical, Ltd. | ESL FDA AI Device Intelligence